-Menu settings with the button FUNCTION
-Setting time intervals for timer operation
Press the button
until the display indicates "Interval Set”. Use the
FUNCTION
buttons
and
to adjust the intervals between the individual fog outputs in
UP
DOWN
timer mode within the range of 10 and 300 seconds.
-Setting the output duration for timer operation
Press the button
until the display indicates "Duration Set”. Use the
FUNCTION
buttons
and
to adjust the duration of the fog outputs in timer mode within
UP
DOWN
the range of 10 and 100 seconds.
-Setting the fog output volume
Press the button
until the display indicates "Volume Out”. Use the
FUNCTION
buttons
and
to select one of four default settings for the fog output volume:
UP
DOWN
.
• Nonstop Burst -- The machine will continuously produce low fog. The output volume
is automatically adjusted by the machine based on the operating temperature.
• High Volume -- about 60 % output volume
• Medium Volume -- about 52 % output volume
• Low Volume -- about 35 % output volume
* When set to "Nonstop Burst" or "Low Volume", the machine
.
will continuously produce low fog
However, the setting "Nonstop Burst" will produce the higher output volume.
* Please suspend the operation for 5 minutes before switching from the setting "Nonstop Burst" to the
setting "High Volume" or "Medium Volume".
-Setting the
512 address
DMX
Press the button
until the display indicates "
512 Add." Use the
FUNCTION
DMX
buttons
and
, to set the machine to the same address as on your
UP
DOWN
DMX
controller. Please refer to the chapter
512 settings for more information on
DMX
DMX operation.
-Timer operation
In the time mode, the machine will automatically emit fog. The time intervals, duration,
and fog volume depend on the corresponding menu settings. Press the button
, to
TIMER
activate the timer mode. The display indicates the set time interval. The unit counts down
to 0 seconds and emits fog. To deactivate the timer mode, press the button
again.
TIMER
-Continuous operation
Press the button
, to activate continuous fog output. The display indicates the
VOLUME
value that was set in menu item "Volume Out” i.e. Nonstop Burst, High, Medium or Low. To
stop the fog output, press the button
once again.
VOLUME
-Manual operation
For immediate fog output at the maximum volume of fog, keep the button MANUAL
pressed. The display indicates "Manual Output". As soon as you release the button, the
fog output will stop. The manual operation will take priority over the continuous operation
and the timer operation. Even if one of these operating modes is activated, the fog
machine will always emit the maximum volume of fog when the button
is
MANUAL
pressed.
Output volume
Output duration
Pause between fog ouputs
Nonstop Burst
Continuous output*
--
High Volume
1 minute
1 minute
Medium Volume
2 Minute
1 minute
Low Volume
Continuous output*
--
D
N
G
-200
User Manual
04
English
Содержание DNG-200
Страница 2: ...English 01 07 08 15 16 22 Fran ais 23 29 German...
Страница 31: ......