- 4 -
Life:
The expected service life of the toilet lift seat can be up to 5 years if used as intended, in accordance with safety and
maintenance instructions. Beyond this period,
the toilet seat lift will continue to be used in safe condition.
Cleaning:
- easy to clean, free of external rough surfaces
- do not use abrasive or scouring cleaning agents.
- if any defects or damage appear, please inform the supplier immediately. Do not use the product if it is suspected
of being damaged or missing parts.
- clean it with hot water and soap or with soft detergents.
Disinfection by wiping
With commercially available disinfectants according to EN 12720
1. Put on protective gloves before preparing the product
2. Spray the areas to be treated with a disinfectant
3. Rub the treated areas with a paper towel, if necessary. Try again
4. Discard protective gloves and paper towels
Contraindications
- Troubled perceptual
- Severe balance disorders
- Inability to sit
METHOD OF DISPOSAL OF THE PRODUCT AFTER REMOVING FROM SERVICE
After the device is withdrawn from use, the medical device can be disposed of as normal household waste, except
for electrical products - proceed in the manner appropriate for the disposal of electrical and electronic equipment.
NOTES
1. During use and during the assembly and adjustment of the mechanisms, there may be a risk that parts of the
user/caregiver’s body will be trapped and/or compressed in the openings/spaces between the elements.
2. After adjustment, stabilize the position by tightening the nuts/bolts.
3. Before each use of the product, check that all adjustable parts are securely attached.
4. Beware of wet or slippery surfaces.
5. Do not place your fingers in seat holes that drain water. This can cause your fingers to be compressed or pinched.
6. Do not use a defective or broken booster seat.
7. Keep the product away from children. The maximum load does not apply to the cover.
8. The blanket is not intended to sit.
9. The elevation of the toilet is not intended to be seated permanently.
10. By lowering the armrests, clothes or body parts can be pinched.
11. Missing, damaged or worn parts can only be replaced by an approved service.
12. Do not use pressure washers or harsh, corrosive detergents for cleaning.
WARNING:
In the event of a device-related “serious incident”, which directly or indirectly led to, could have led to, or is likely to
lead to any of the following events:
a) death of a patient, user or another person, or
b) temporary or permanent deterioration of the health of a patient, user or another person, or
c) a serious risk to public health, such a “serious incident” must be notified to the manufacturer and to the competent
authority of the Member State, in which the user or patient resides. For Poland, the competent authority is the
Office for Registration of Medicinal Products, Medical Devices and Biocidal Products.
WARNING:
In the event of pain, allergic reactions or other alarming, unclear symptoms related to the use of the medical device,
please consult a healthcare professional.