background image

RS422/485 to USB Adapter with Isolation and Surge Protection

 

 

 

2

 

 

 

 

 

RS485 User:  Since the factory settings are initially  set at 2-wire 
RS485 mode. There is no need to change any switch settings 
from the default settings. 

 

RS422 User: Change the mode pin to “422” positions(ON). Keep 
the other settings unchanged.   

Switch Description: 

 

Switch 

Pin# 

Switch Name 

(Switch States) 

Switch Positions   

Description 

485/422 

(OFF/ON) 

485 

(Default) 

2-wire RS485 mode 

422 

4-wire RS422 mode 

ECHO/NO ECHO 

(OFF/ON) 

ECHO 

Transmitting data will be 

echoed back 

NO ECHO 

(Default) 

No echo data 

NO TERM/TERM 

(OFF/ON) 

NO TERM 

(Default) 

Termination Resistor is 

Disabled 

TERM 

Termination Resistor is 

Enabled 

RVD 

 

(OFF) 

Reserved for Future Use 

(ON) 

Reserved for Future Use 

 

 

Please note that if the mode were set at “422” mode, the ECHO setting 
will take no effect. 

 

The Echo mode is useful for the application program to detect if the 
RS485 bus were in a collision. If the echoed data was not equal to the 
transmitted data, then the bus was in a collision. 

 
 

The RS422/485 Adapter Cable can be hot-plugged to the USB port of 

your computer  due to the specifications of USB. It supports the 

following operating systems. The drivers are shipped in the 

corresponding  folder on the supplied driver CD.  If you are installing 

drivers for Win98, ME, 2000, 2003, XP or Vista, when prompted for the 

3. Installing Drivers   

2. Switch Settings 