User’s Manual Version 1.
4
Serial to Ethernet Device Server
STE-501C
Copyright © 201
7
Antaira Technologies, LLC
All rights reserved.
16
LINK Mode Setup
Configure STE-501C as TCP server
:
(Figure 3.10)
Type
1
from “
Input choice and enter (1~4):
” of COM1
Type
1
in the “
Input choice(1~5) and enter
:
”
Input local port in the “
Please input local port
:
”
1.If one want to enable IP filter
:
Input
y
in the “
Do one want to enable IP filter(y/n)?
”
Input source IP in the “
Please input Filter_IP
:
”
Double click “
Enter
” key
2.If one don’t want to enable IP filter
:
Input
n
in the “
Do one want to enable IP filter(y/n)?
”
Double click “
Enter
” key
Input idle time in “
Please input idle time to send TCP alive packet(4*10sec)
:
”(If one input
2
->the
sending TCP keep alive packet period will be change to 2*10 sec)
Note:
1.
IP filtering function is disabled if setting FILTER_IP to “0.0.0.0”.
2.
IP filter is disabled by default
3.
If IP filter is enabled, only source IP assigned can connect to STE-501C.
Figure 3.10 Link Mode-TCP server setup