2.6 Cabling
Twisted-pair segments can be connected with an unshielded twisted pair (UTP) or shielded
twisted pair (STP) cable. The cable must comply with the IEEE 802.3u 100Base TX standard
(e.g. Category 5, 5e, or 6, 6e). The cable between the equipment and the link partner (switch,
hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
Note: Cable size should be between 18~20 AWG and the torque should be tightened to 5lbs.
2.7 Wiring the Power Inputs
Please follow the below steps to insert the power wire.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in Figure 2.6.
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure
2.7.
Figure 2.7
Power Terminal Block
Figure 2.6
Power Terminal Block