Antaira Industrial Ethernet Switches
LNX-500A Series User Manual V2.0
7
2.6 Cabling
Use the four twisted-pair Category 5e or above cabling for RJ-45 port connection. The cable
between the switch and the link partner (switch, hub, workstation, etc.) must be less
than100meters (328ft.) long.
2.7 Wiring the Power Inputs
Please follow below steps to insert the power wire.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-)
contacts on the terminal block connector as shown below in
Figure 2.6
.
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in
Figure
2.7.
Note
Only use copper conductors,
60/75
°
C
,tighten to
5lbs.
The wire gauge for the terminal block should range between
18~20 AWG
.
Figure2.7
Power Terminal Block
Figure2.6
Power Terminal Block