2.4 Grounding
Grounding and wire routing help limit the effects of noise due to electromagnetic interference
(EMI). Run the ground connection from the ground screw to the grounding surface prior to
connecting devices. The industrial Ethernet switch provides two ground holes which are on the
top and bottom of the wall mounting metal plate which are the same as wall mounting holes. It is
recommended to use a M3 or M4 ground screw and grounding wire, and attach the wire to either
ground hole with the screw. The grounding holes are shown below in
Figure 2.3.
Figure 2.3
Caution
: Using a shielded cable achieves better electromagnetic compatibility.
2.5 Ethernet Ports
M12 Interface (Auto MDI/MDIX)
◼
Connection Format: M12 4-Pin D-Coded Female Connector
◼
Transmission Rate: 10 Mbit/s or 100 Mbit/s
Prepare the M12 4-Pin D-Coded Ethernet Port mating cable for Ethernet connection. The M12 D-
Coded Ethernet ports
are auto-sensing for 10Base-T or 100Base-TX device connections. Auto
MDI/MDIX means that you can connect to another switch or workstation without changing straight-
through or crossover cabling. See pin assignment shown in
Table 2.2
.