background image

Antaira Technologies - Industrial Ethernet Switches
LNP-800AGH Series - Hardware Manual - v1.0

Figure 2.3 - Top View Panel

2.4 LED Indicators

There are LED light indicators located on the front panel of the industrial Ethernet switch that display the power status and

network status. Each LED indicator has a different color and has its own specific meaning, see below in Table 2.1.

LED

Color

Description

P1

Green

On

Power Input 1 is active

Off

Power Input 1 is inactive

P2

Green

On

Power Input 2 is active

Off

Power Input 2 is inactive

Fault

Red

On

Power Input 1 or 2 is inactive

Off

Power Input 1 and 2 are both functional

LAN Port 1~8

(Upper LED)

Green

On

Connected to network, 10/100/1000Mbps

Flashing

Networking is active

Off

Not connected to network

LAN Port 1~8

(Lower LED)

Green

On

The port is supplying power to the powered-device

Off

No powered-device attached or power supplying fails

Table 2.1 - LED Indicators

Note: “P1” is the abbreviation for “Power 1”, “P2” is for “Power 2”, “LNK” is for “Link”, and “ACT” is for “Activity”.

5

Содержание LNP-800AGH Series

Страница 1: ...LNP 800AGH Series 8 Port Industrial Gigabit PoE Unmanaged Ethernet Switch with 8 10 100 1000Tx Ports 30W Port 48 55VDC Power Input Hardware Manual Version 1 0 April 2021 ...

Страница 2: ...ogies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be incorporated into later versions of the manual The information contained is subject to change without prior notice FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital de...

Страница 3: ...à essayer de corriger les interférences par une ou plusieurs des mesures suivantes Réorientez ou déplacez l antenne de réception Augmentez la distance entre l équipement et le récepteur Connectez l équipement à une prise sur un circuit différent de celui auquel le récepteur est connecté Consultez le revendeur ou un technicien radio TV expérimenté pour obtenir de l aide CE Mark Warning This is a Cl...

Страница 4: ... Dimensions 3 2 2 Front View Panel 4 2 3 Top View Panel 4 2 4 LED Indicators 5 2 5 DIP Switch Function 6 2 6 Ethernet Ports 6 2 7 Cabling 7 2 8 Wiring the Power Inputs 7 2 9 Wiring the Fault Alarm Contact 8 2 10 Grounding Note 9 3 Mounting Installation 10 3 1 DIN Rail Mounting 10 3 2 Wall Mounting 11 4 Hardware Installation 13 4 1 Installation Steps 13 4 2 Maintenance and Service 14 4 3 Troublesho...

Страница 5: ...nterface and Performance All RJ45 ports support Auto MDI MDI X Function Embedded 8 10 100 1000Tx RJ45 ports with IEEE 802 3at Compliant 30W Port Store and forward switching architecture 8K MAC address table 9 6Kbytes Jumbo Frame support Power Input DC 48 55V redundant with a 6 pin removal terminal block Max current 5A Max PoE output 240W The power input specification complies with the requirements...

Страница 6: ...d alimentation Les spécifications matérielles les ports les informations de câblage et l installation du câblage du commutateur Ethernet industriel seront décrits dans ce manuel d utilisation Warning Labels The caution label means that you should check certain information on the user manual when working with the device Shown in Figure 1 1 Étiquettes d avertissement L étiquette d avertissement sign...

Страница 7: ...ernet Switches LNP 800AGH Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 54mm x 99mm x 142mm Figure 2 1 Physical Dimensions 3 ...

Страница 8: ...et Switches LNP 800AGH Series Hardware Manual v1 0 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View Panel 2 3 Top View Panel Figure 2 3 below shows the top panel of the product series 4 ...

Страница 9: ...n On Power Input 1 is active Off Power Input 1 is inactive P2 Green On Power Input 2 is active Off Power Input 2 is inactive Fault Red On Power Input 1 or 2 is inactive Off Power Input 1 and 2 are both functional LAN Port 1 8 Upper LED Green On Connected to network 10 100 1000Mbps Flashing Networking is active Off Not connected to network LAN Port 1 8 Lower LED Green On The port is supplying power...

Страница 10: ... connections Auto MDI means that the switch can connect to another switch or workstation without changing the straight through or crossover cabling See the figures below for straight through and crossover cabling schematics RJ45 Pin Assignments Crossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX...

Страница 11: ... is a compact optical transceiver used in optical communications for both telecommunication and data communication applications Caution Please employ optional optical transceiver SFP Fixed Fiber that complies with IEC 60825 1 and classified as Class 1 laser product Attention Veuillez utiliser un émetteur récepteur optique en option SFP fibre fixe conforme à la norme IEC 60825 1 et classé comme pro...

Страница 12: ...AWG Attention Utilisez uniquement des conducteurs en cuivre 125 C serrez à 5 lb Le calibre des fils du bornier doit être compris entre 18 et 20 AWG 2 9 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2 8 By inserting the wires it will detect the fault status including power failure or port link failure man...

Страница 13: ... alimentation connectez les broches 1 à 5 et les broches 2 à 6 pour éliminer l alarme de panne de courant 2 10 Grounding Note Grounding and wire routing help limit the effects of noise due to Electromagnetic Interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown below in Figure 2 9 Figure 2 9 Groundi...

Страница 14: ...rear side of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figur...

Страница 15: ... industriel 1 Remove the DIN Rail bracket from the industrial Ethernet switch by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l app...

Страница 16: ...trial Ethernet Switches LNP 800AGH Series Hardware Manual v1 0 Figure 3 4 Remove DIN Rail bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mounting Bracket Dimensions 12 ...

Страница 17: ...f it is required to wall mount the industrial Ethernet switch please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on For the help on how to wire power please refer to the Wiring the Pow...

Страница 18: ...is being used Never use a power supply or adapter with a non compliant DC output voltage or it will burn the equipment Select the proper UTP or STP cable in order to construct the network Use an unshielded twisted pair UTP or shield twisted pair STP cable for RJ45 connections 100Ω Category 5e for 10 100Mbps Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 ...

Страница 19: ...e Transfer Rate 14 880pps for 10Base T Ethernet 148 800pps for 100Base T Fast Ethernet 1 488 000pps for Gigabit Ethernet Packet Buffer 4Mbits Jumbo Frame 9 6Kbytes MAC Table Size 8K Port Interface Ethernet Port 8 10 100 1000BaseTx with PoE 30W Port Auto negotiation speed Full Half duplex mode and auto MDI MDI X connection PoE Port Pin Assignment V V V V for pin 1 2 3 6 Endspan MDI Alternative A LE...

Страница 20: ...own Fuse Reverse Polarity Protection Present System Power Consumption 8 Watts Max PoE Power Budget 240W Environmental Limits Operating Temperature STD 10 C to 65 C EOT 40 C to 75 C Storage Temperature 40 C 85 C Ambient Relative Humidity 5 to 95 non condensing Regulatory Approvals EMI FCC Part 15 Subpart B Class A CE EN55032 EN61000 6 4 Class A EMS CE EN55024 EN61000 6 2 Class A EN61000 4 2 3 4 5 6...

Страница 21: ... Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira Asia Office 886 2 2218 9733 Please report any problems to Antaira www antaira com support antaira com www antaira eu info antaira eu www antaira com tw info antaira com tw Any changes to this material will be announced on the Antaira website 17 ...