background image

Antaira Industrial Ethernet Switches 

LNP-0802C-SFP series User Manual V1.2 

 

 

 

 

 

 

LNP-0802C-SFP Series

 

8-Port Industrial PoE+ Unmanaged Ethernet Switches, with 

6*10/100Tx (30W/Port), 2* Gigabit Combo Ports (2*10/100/1000Tx 

RJ45, and 2* 100/1000 SFP Slots) 

 

 

 

 

 

 

 

 

 

 

User Manual 

Version 1.2 

 

 

 

 

Содержание LNP-0802C-SFP Series

Страница 1: ...tches LNP 0802C SFP series User Manual V1 2 i LNP 0802C SFP Series 8 Port Industrial PoE Unmanaged Ethernet Switches with 6 10 100Tx 30W Port 2 Gigabit Combo Ports 2 10 100 1000Tx RJ45 and 2 100 1000 SFP Slots User Manual Version 1 2 ...

Страница 2: ...rs Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability...

Страница 3: ...to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expressly ...

Страница 4: ...cal Dimensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 6 2 6 Cabling 8 2 6 1 Gigabit Combo Port Copper SFP mini GBIC 8 2 7 Wiring the Power Inputs 11 2 8Wiring the Fault Alarm Contact 12 3 Mounting Installation 13 3 1 DIN Rail Mounting 13 3 2Wall Mounting 15 4 Hardware Installation 16 4 1 Installation Steps 16 5 Network Application 17 6 Trouble Shooting 18 7 Tech...

Страница 5: ...built in relay warning function alerts maintainers when power failures occur The LNP 0802C SFP series includes two models one with an operating temperature range of 10 to 70 C and the other one with an extended operating temperature range of 40 to 75 C It is a perfectly designed product to fulfill any special needs for industrial automation outdoor applications and harsh weather environments 1 1 K...

Страница 6: ...2 10 100 1000Tx RJ45 and 2 100 1000 SFP slots 1 User manual 1 Product CD 2 Wall mounting brackets and screws 1 DC cable 18 AWG DC jack 5 5x2 1mm 1 3 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be describ...

Страница 7: ...al Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies LNP 0802C SFP series 8 port industrial PoE unmanaged switches with 6 10 100Tx 30W port 2 Gigabit combo ports 2 10 100 1000Tx RJ45 and 2 100 1000 SFP slots W x D x H is 46mm x 99mm x 142mm Figure 2 1 LNP 0802C SFP Series Physical Dimensions ...

Страница 8: ... 100Tx 30W Port 2 Gigabit combo ports 2 10 100 1000Tx RJ45 and 2 100 1000 SFP slots is shown below in Figure 2 2 2 3 Top View Figure 2 3 below shows the top panel of the LNP 0802C SFP series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 48 55VDC Figure 2 2 The Front Panel of the LNP 0802C SFP Series Figure 2 3 Top Panel View of LNP 0802C SFP Serie...

Страница 9: ...bled PoE Indicators Port 1 6 Green On The port is supplying PoE power Off No powered device attached or power supplying fails LAN Port 1 6 Upper LED Green On Connected to network 100Mbps Flashing Networking is active Off Not connected to network LAN Port 1 6 Lower LED Green On Connected to network 10Mbps Flashing Networking is active Off Not connected to network Gigabit Combo Port LED Indicators L...

Страница 10: ... Tx 6 Tx All ports on this industrial Ethernet switch support automatic MDI MDI X operation Users can use straight through cables see figure below for all network connections to PCs servers other switches or hubs With straight through cable pins 1 2 3 and 6 are at one end of the cable and are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 sho...

Страница 11: ... cabling schematics for straight through and crossover The following figures show the 10 and 100 Ethernet RJ 45 pin outs Figure 2 6 RJ45 Ethernet Port Pin Outs Figure 2 4 Straight Through Cable Schematic Figure 2 5 Crossover Cable Schematic Figure 2 7 Straight Through Cable Schematic Figure 2 8 Crossover Cable Schematic ...

Страница 12: ...iver used in optical communications for both telecommunication and data communications The SFP slots support dual rate mode which can switch the connection speed between 100 and 1000Mbps They are used for connecting to the network segment with single or multi mode fiber Users must first choose the appropriate SFP transceiver to plug into the slots and then choose the proper multi mode or single mo...

Страница 13: ...sceiver and LC cable please follow the steps below First insert the SFP transceiver module into the SFP slot as shown below in Figure 2 9 Notice that the triangle mark is at the bottom of the SFP slot Figure 2 10 shows SFP transceiver module was inserted Second insert the fiber cable of the LC connector into the transceiver as shown below in Figure 2 11 Figure 2 9 Transceiver to the SFP Module Fig...

Страница 14: ...r please follow the steps shown below 1 Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 12 2 Push down the metal clasp and pull the transceiver out by the plastic part as shown below in Figure 2 13 Figure 2 12 Remove LC Connector Figure 2 13 Pull Out from the SFP Module ...

Страница 15: ...tive wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 14 2 Tighten the wire clamp screws to prevent the wires from loosening as shown below in Figure 2 15 Note Only use copper conductors 60 75 C tighten to 5 lbs The wire gauge for the terminal block should range between 18 20 AWG Figure 2 15 Power Terminal Block Figure 2 14 Power Terminal...

Страница 16: ...the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is shown below in Figure 2 16 Note The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate the power...

Страница 17: ...nstallation 3 1 DIN Rail Mounting The DIN Rail is pre installed on the industrial Ethernet switch from the factory If the DIN Rail is not on the industrial Ethernet switch please see Figure 3 1 to learn how to install the DIN Rail on the switch Figure 3 1 The Rear Side of the Switch and DIN Rail Bracket ...

Страница 18: ...racket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 Check if the bracket is mounted tightly on the rail 6 To remove the industrial Ethernet switch from the rail do the opposite from the abov...

Страница 19: ... Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opposite from the steps above Below in Figure 3 5 are the dimensio...

Страница 20: ...he Wall Mounting section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on If you need help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light ...

Страница 21: ...Ethernet Switches LNP 0802C SFP Series User Manual V1 2 17 5 Network Application This segment provides an example of an industrial Ethernet switch application Figure 5 1 Figure 5 1 Industrial PoE Ethernet Switch Application Reference ...

Страница 22: ...Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose power connections power ...

Страница 23: ...ernet port 1 488 000pps for gigabit Ethernet port Transmission Distance Up to 100M Transmission Speed Up to 1000Mbps MAC Address 8K table size RJ45 Ethernet Port 6 10 100Tx 30W Port 2 10 100 1000Tx Gigabit combo auto negotiation speed full half duplex mode and auto MDI MDI X connection PoE Pin Assignment RJ 45 port 1 4 support IEEE 802 3at end point alternative A mode Positive VCC Pin 1 2 Negative...

Страница 24: ... to 95 Non Condensing Storage Temperature 40oC to 85oC 40 F 185 F Case Dimension IP 30 46mm W x 99mm D x 142mm H EMI FCC Class A CE EN61000 4 2 3 4 5 6 8 CE EN61000 6 2 CE EN61000 6 4 Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Safety CE FCC UL 61010 1 UL 61010 2 201 UL Class 1 Division 2 ISA 12 12 01 Table 7 1 LNP 0802C SFP Series Technical Specifications ...

Отзывы: