2.6 Cabling
Twisted-pair segments can be connected with an unshielded twisted pair (UTP) or shielded
twisted pair (STP) cable. The cable must comply with the IEEE 802.3u 100Base TX standard
(e.g. Category 5, 5e, or 6). The cable between the equipment and the link partner (switch, hub,
workstation, etc.) must be less than 100 meters (328 ft.) long.
Fiber segment using single-mode connector type must use 9/125μm single-mode fiber
cable.
Fiber segment using multi-mode connector type must use 50 or 62.5/125 μm multi-mode
fiber cable.
2.7 Wiring the Power Inputs
Please follow the below steps to insert the power wire.
1. Insert the positive and negative wires into the PWR1 (V1+, V1-) and PWR2 (V2+, V2-) contacts
on the terminal block connector as shown below in Figure 2.7.
2. Tighten the wire-clamp screws to prevent the wires from loosening, as shown below in Figure
2.8.
**Note:
Only use copper conductors, 60/75°C, tighten to 5 lbs.
The wire gauge for the terminal block should range between 18~20 AWG.
Figure 2.8
Power Terminal Block
Figure 2.7
Power Terminal Block