Antaira Technologies - Industrial Ethernet Switches
LMP-C602G-SFP-bt-V2 Series - Hardware Manual - v1.0
* Note:
When the relay is triggered because of event 2~5, the relay contact alarm will update the status every 30
seconds. If there is no event happening for 30 seconds, the relay contact alarm will be turned off. If the
user disables the failed PoE port by removing the cable or DIP switch manually, the relay will be recovered
immediately.
2.7 Reset Button
There is a “reset” button located on the top panel of the industrial Ethernet switch that helps users to
reboot, restore default, or save running configurations by pressing the button for different seconds.
Please refer to Table 2.3 for the timing and function.
Table 2.3 - Reset Button Functions
2.8 Ethernet Ports
●
RJ45 Ports
RJ45 Ports (Auto MDI/MDI-X): The RJ45 ports are auto-sensing for 10Base-T, 100Base-TX, or
1000Base-T connections. Auto MDI means that the switch can connect to another switch or workstation
without changing the straight-through or crossover cabling. See the figures below for straight-through and
crossover cabling schematics.
●
RJ45 Pin Assignments
Table 2.4 - 10/100Base-T(X) RJ45 Pin Assignments
11
Seconds
Function
Fault LED
0s < t (press time) < 4s
Reboot the switch
LED is flashing with green color
4s < t (press time)
Restore factory default
LED is flashing with green and red color
Crossover Cable
Straight Through Cable
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
Pin Number / Signal
1 / RX+
3 / TX+
1 / RX+
1 / TX+
2 / RX-
6 / TX-
2 / RX-
2 / TX-
3 / TX+
1 / RX+
3 / TX+
3 / RX+
6 / TX-
2 / RX-
6 / TX-
6 / RX-