background image

Antaira Technologies - Industrial Ethernet Switches 
LMP-0702G-SFP-bt-V2 Series - Hardware Manual - v1.0 

 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected. 

Consult the dealer or an experienced radio/TV technician for help. 

 

Caution:​ Any changes or modifications not expressly approved by the grantee of this device could void 

the user’s authority to operate the equipment. 

 

Avertissement FCC 

Cet équipement a été testé et déclaré conforme aux limites d'un appareil numérique de classe A, 

conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection 

raisonnable contre les interférences nuisibles dans une installation résidentielle. Cet équipement génère, 

utilise et peut émettre de l'énergie radiofréquence. Cela peut provoquer des interférences nuisibles aux 

communications radio si l'équipement n'est pas installé et utilisé conformément aux instructions. 

Cependant, il n'y a aucune garantie qu'aucune interférence ne se produira dans une installation 

particulière. Si cet équipement provoque des interférences nuisibles à la réception radio ou télévision, ce 

qui peut être déterminé en éteignant puis en rallumant l'équipement, l'utilisateur est encouragé à essayer 

de corriger les interférences par une ou plusieurs des mesures suivantes: 

Réorientez ou déplacez l'antenne de réception. 

Augmentez la distance entre l'équipement et le récepteur. 

Connectez l'équipement à une prise sur un circuit différent de celui auquel le récepteur est 

connecté. 

Consultez le revendeur ou un technicien radio / TV expérimenté pour obtenir de l'aide. 

 

CE Mark Warning 

This is a Class-A product. In a domestic environment, this product may cause radio interference in which 

case the user may be required to take adequate measures. 

 

Avertissement de marque CE

 

Ceci est un produit de classe A. Dans un environnement domestique, ce produit peut provoquer des 

interférences radio, auquel cas l'utilisateur peut être amené à prendre des mesures adéquates. 

Содержание LMP-0702G-SFP-bt-V2 Series

Страница 1: ...SFP bt V2 Series 7 Port Industrial Gigabit IEEE 802 3bt PoE Light Layer 3 Managed Ethernet Switch with 4 10 100 1000Tx 90W Port 1 10 100 1000Tx and 2 100 1000 SFP Ports Hardware Manual Version 1 0 Nov...

Страница 2: ...y and fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice A...

Страница 3: ...communications radio si l quipement n est pas install et utilis conform ment aux instructions Cependant il n y a aucune garantie qu aucune interf rence ne se produira dans une installation particuli r...

Страница 4: ...trial Grade Managed Ethernet Switches Hardware Manual Version 1 0 November 2020 The manual supports the following models LMP 0702G SFP bt V2 LMP 0702G SFP bt T V2 This document is the current official...

Страница 5: ...View Panel 5 2 3 Top View Panel 5 2 4 LED Indicators 6 2 5 PoE Port LED Indicators 8 2 6 DIP Switch 10 2 7 Relay Contact Alarm Warning 11 2 8 Reset Button 11 2 9 Ethernet Ports 12 2 10 Cabling 13 2 1...

Страница 6: ...o 65 C or an extended temperature range EOT 40 C to 75 C 1 1 Product Hardware Features System Interface and Performance All RJ45 ports support Auto MDI MDI X Function Embedded 4 10 100 1000Tx 90W Port...

Страница 7: ...port IGMP snooping v1 v2 v3 IGMP filtering throttling IGMP query up to 1024 group Supports IPv4 IPv6 RMON MIB II port mirroring event syslog DNS NTP SNTP HTTPS SSH SSL TFTP MODBUS TCP for SCADA system...

Страница 8: ...entr e d alimentation Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage du commutateur Ethernet industriel seront d crits dans ce manuel d utilisation W...

Страница 9: ...Switches LMP 0702G SFP bt V2 Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 54mm x 99mm...

Страница 10: ...2G SFP bt V2 Series Hardware Manual v1 0 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View Panel 2 3 Top View Panel Figure 2 3 below shows the top...

Страница 11: ...s inactive Power 2 Green On Power Input 2 is active Off Power Input 2 is inactive Status Green On No event happened by software setting Red On System booting Event happened by software setting Master...

Страница 12: ...f at connection Single Signature PD Class 0 4 Flashing Port link is recovered from failure event Off No powered device attached or power supplying fails Green Amber Alternating Flashing The port is tr...

Страница 13: ...t is overloaded 100 the PoE port of the lowest priority PoE port will be shut down The PoE LED of the port will act cyclically as below until the port is recovered from the event Figure 2 4 PoE Budget...

Страница 14: ...ator is clear manually Figure 2 7 PoE Over Current Recovering LED Sequence IEEE 802 3af at Amber IEEE 802 3bt Green Cable Short Event When the working PD encounters a cable short event the PoE port LE...

Страница 15: ...nt the PoE LED of the port will act cyclically as below until the event indicator is clear manually Figure 2 11 PoE Dual PD Recovering LED Sequence IEEE 802 3af at Amber IEEE 802 3bt Green Notice 1 Th...

Страница 16: ...tus every 30 seconds If there is no event happening for 30 seconds the relay contact alarm will be turned off If the user disables the failed PoE port by removing the cable or DIP switch manually the...

Страница 17: ...s Table 2 4 10 100Base T X RJ45 Pin Assignments Table 2 5 1000Base T RJ45 Pin Assignments Note and signs represent the polarity of the wires that make up each wire pair 12 Crossover Cable Straight Thr...

Страница 18: ...l transceiver SFP Fixed Fiber that complies with IEC 60825 1 and classified as Class 1 laser product Attention Veuillez utiliser un metteur r cepteur optique en option SFP fibre fixe conforme la norme...

Страница 19: ...eurs en cuivre 125 C serrez 5 lb Le calibre des fils du bornier doit tre compris entre 18 et 20 AWG 2 12 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block c...

Страница 20: ...rce d alimentation connectez les broches 1 5 et les broches 2 6 pour liminer l alarme de panne de courant 2 13 Grounding Note Grounding and wire routing help limit the effects of noise due to Electrom...

Страница 21: ...he rear side of the industrial Ethernet switch Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2...

Страница 22: ...ande industriel 1 Remove the DIN Rail bracket from the industrial Ethernet switch by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 U...

Страница 23: ...Ethernet Switches LMP 0702G SFP bt V2 Series Hardware Manual v1 0 Figure 3 4 Remove DIN Rail bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall...

Страница 24: ...switch If the DIN Rail is not screwed on the industrial Ethernet switch please refer to the DIN Rail Mounting section for DIN Rail installation If it is required to wall mount the industrial Ethernet...

Страница 25: ...tion holes located in the different faces of the device This may not only harm the internal layout but might cause harm to users as well Do not under any circumstance open the device for any reason Pl...

Страница 26: ...problem with the power cord Check for loose power connections power losses or surges at the power outlet Please contact Antaira for technical support service if the problem still cannot be resolved I...

Страница 27: ...duler mode Power Saving ActiPHY PerfectReach IEEE 802 3az EEE power management Network Redundancy STP RSTP MSTP port trunk with LACP ERPS v1 v2 50ms Configuration Http Https Telnet SSH CLI TFTP SNMP v...

Страница 28: ...d Link Active PoE On connected to PD devices SFP Link Active Protection Network Cable 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m 100Base TX 2 pair 2 pair UTP STP Cat 5 cable EIA...

Страница 29: ...nced on the Antaira website 24 Reverse Polarity Protection Present PoE Pin Assignment V V V V for pin 1 2 3 6 V V V V for pin 4 5 7 8 Support Modes Mode A Mode B 4 Pair Mode PoE Power Budget 240W 48 5...