Antaira Industrial Ethernet Switches 

LMP-0501-24 Series User Manual V1.1 

 

 

 

 

 

 

LMP-0501-24 Series

 

5-Port Industrial PoE+ Managed Ethernet Switches   

4*10/100Tx (30W/Port), 1*100Fx,   

12~36VDC (Voltage Booster) Power Input 

 

 

 

 

 

 

 

 

 

 

User Manual 

Version 1.1 

 

 

 

Содержание LMP-0501-24 Series

Страница 1: ...ial Ethernet Switches LMP 0501 24 Series User Manual V1 1 i LMP 0501 24 Series 5 Port Industrial PoE Managed Ethernet Switches 4 10 100Tx 30W Port 1 100Fx 12 36VDC Voltage Booster Power Input User Man...

Страница 2: ...Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the c...

Страница 3: ...ollowing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which t...

Страница 4: ...sions 4 2 2 Front Panel 5 2 3 Top View 5 2 4 LED Indicators 6 2 5 Ethernet Ports 7 2 6 Fiber Port 8 2 7 Cabling 8 2 8 Wiring the Power Inputs 9 2 9 Wiring the Fault Alarm Contact 9 3 Mounting Installa...

Страница 5: ...Schedule 21 5 5 ERPS 22 5 5 1 ERPS Status 23 5 5 2 ERPS Configuration 23 5 6 Spanning Tree 32 5 6 1 RSTP Status 33 5 6 2 RSTP Configuration 33 5 6 3 MSTI Status 35 5 6 4 MSTI Configuration 36 5 7 802...

Страница 6: ...Log 49 5 12 3 SMTP Setting 50 5 12 4 Event Selection 51 5 12 5 Fault Alarm 51 5 13 MAC Table 52 5 13 1 MAC Address Table 52 5 13 2 MAC Table Configuration 52 5 14 Maintenance 53 5 14 1 Upgrade 53 5 14...

Страница 7: ...s is IP30 rated and DIN rail mountable that provides a standard operating temperature range 10 C to 70 C and an extended operating temperature range 40 C to 75 C It also designed with high EFT and ESD...

Страница 8: ...ore and forward switching architecture 8K MAC address table Power line EFT protection 2 000VDC Ethernet ESD protection 6 000VDC Power Input DC 12 36V redundant with built in voltage booster and a 6 pi...

Страница 9: ...Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling...

Страница 10: ...Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira s LMP 0501 24 series 5 Port industrial PoE managed Ethernet switch with 4 10 100Tx 30W Port and 1 100Fx SC ST fiber ports...

Страница 11: ...ial PoE managed Ethernet switches is shown below in Figure 2 2 2 3 Top View Figure 2 3 below shows the top panel of the LMP 0501 24 series switch that is equipped with one 6 pin removal terminal block...

Страница 12: ...On System is ready Off System is booting Red On Fault Alarm Off System is in normal state Owner Green On ERPS Owner Mode Ring Master is ready Off ERPS Owner Mode is not active Ring Green On Ring Netwo...

Страница 13: ...for all network connections to PCs servers other switches or hubs With straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other e...

Страница 14: ...ill cause the port cannot work normally Caution This is a Class 1 Laser LED product Don t stare into the Laser LED Beam 2 7 Cabling Twisted pair segments can be connected with an unshielded twisted pa...

Страница 15: ...5lbs The wire gauge for the terminal block should range between 18 20 AWG 2 9 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture sh...

Страница 16: ...Rail bracket on the rear side of the industrial Ethernet switch 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch in...

Страница 17: ...e wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corne...

Страница 18: ...tion for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then...

Страница 19: ...ith advanced management features that allow users to manage the switch from anywhere on the network through any Internet browser such as Internet Explorer version 9 0 or above is recommended Firefox C...

Страница 20: ...Click Login button then the main status page of the Web Console will appear as below Figure 5 2 The online image of the switch will display the real time ports connection status 5 2 Basic Setting 5 2...

Страница 21: ...ame label to describe this PoE Managed Switch System Location Factory Default blank Users can use this field to insert The physical location of this switch e g telephone closet 3rd floor The maximum a...

Страница 22: ...HCP fails and the configured IP address is zero DHCP will retry If DHCP fails and the configured IP address is non zero DHCP will stop and the configured IP settings will be used The DHCP client will...

Страница 23: ...Apply button to save changes 5 2 4 System Time Terms Value Description Local Time Users can define the switch s local time or click Sync with browser button to have local time setup automatically Sel...

Страница 24: ...provides the current port status 5 3 2 Port Configuration Users can assign or insert a value label for each port under each Port Name box enable or disable each port function state the speed duplex o...

Страница 25: ...ort symmetric and asymmetric mode to avoid packet loss when congestion occurred Click Apply button to save changes Click to undo any changes made locally and revert to previously saved values 5 4PoE P...

Страница 26: ...ble any PoE port function Consumption Set the PoE power output limit value The maximum value must less than 30 0W Click Apply button to save changes 5 4 2 Ping Alarm The PoE ping alarm function is usi...

Страница 27: ...anual V1 1 21 5 4 3 PoE Schedule For energy saving or power recycle powered devices the PoE managed switch s PoE schedule interface allows users to appoint any date and time to enable or disable PoE f...

Страница 28: ...aged Ethernet switches In order to provide users with the flexibility and compatibility when there are any existing switches that contains the standard ERPS protocol Ethernet Ring Protection Switching...

Страница 29: ...atus Below Figure 5 18 shows the network redundancy ring status with the Ethernet Ring Protection Switch ERPS protocol 5 5 2 ERPS Configuration Below Figure 5 19 shows the ERPS configuration interface...

Страница 30: ...fined as Normal node All node roles have the ability to block the port if the link attach to the port is failed and disconnected Ring ID ERPS ring ID ranges from 1 to 239 Ring ID distinguishes differe...

Страница 31: ...sabled due to only one protocol is exclusive running within a switch Below are the steps to disable RSTP or MSTP Step 1 Login the switch with a web browser Step 2 Open the RSTP Configuration page unde...

Страница 32: ...e loop avoidance mechanism ensures the traffic flows on all but the RPL ring link In order to achieve the loop avoidance mechanism ITU T G 8032 defines three roles in ERPS which are RPL Owner Node RPL...

Страница 33: ...e three major roles are required to be configured within the ERPS configuration Figure 5 24 RPL configured Architecture Caution Before enabling any ERPS protocols on any of the Ring Nodes please DO NO...

Страница 34: ...oint Port 1 was chosen as example Step 2 Choose a specific port from the dropdown box next to ring port 1 then set it as Normal from the dropdown box next to Role which locates below ring port 1 At th...

Страница 35: ...d choose a specific port number under Ring Port 0 and set it as the Normal node by clicking the dropdown box of Role then set another specific port number under Ring Port 1 as the Neighbor node as sho...

Страница 36: ...the rest of the managed switches Role of both Ring Port 0 and 1 as Normal Node as shown above in Figure 5 27 Please be sure no duplicate port number has been chosen within a managed switch s ERPS rin...

Страница 37: ...ose the biggest MAC as the blocking node However the user is still required to enable the RRPS protocol and assign a dedicated port number for each uplink port under Ring Port 0 and 1 but there is no...

Страница 38: ...and essentially creates a cascading effect away from the root bridge where each designated bridge proposes to its neighbors to determine if it can make a rapid transition Another extension of RSTP is...

Страница 39: ...anual V1 1 33 5 6 1 RSTP Status Figure 5 30 shows the RSTP algorithm results 5 6 2 RSTP Configuration Users can enable disable the RSTP function and set the parameters for each port Figure 5 30 RSTP I...

Страница 40: ...econds a bridge waits without receiving STP configuration messages before attempting a reconfiguration Path Cost 0 200000000 Enter a value from 1 through 200000000 to define the path cost for the othe...

Страница 41: ...col is applied separately for a set of VLAN s instead of the whole network Different root switches and different STP parameters can be individually configured for each MSTI So one link can be active f...

Страница 42: ...MAC address of the bridge switch Revision User can insert the value from 0 65535 MTSI Instance Instance No VLAN Group There are 1 15 instance number user can insert which VLAN Group info into the belo...

Страница 43: ...fine the path cost value from 1 through 200000000 to the other bridge from this transmitting bridge at the specified port Priority User can decide which port should be blocked by priority in LAN by se...

Страница 44: ...tings Tagged based VLAN is an IEEE 802 1Q specification standard and it is possible to create a VLAN across devices from different switch venders IEEE 802 1Q VLAN uses a technique to insert a tag into...

Страница 45: ...icast group memberships When IGMP snooping is enabled in a switch it analyzes all the IGMP packets between hosts connected to the switch and multicast routers in the network When a switch receives an...

Страница 46: ...8 1 IGMP Settings Terms Value Description IGMP Protocol Check the box to enable or disable IGMP Snooping Querier Switch will be IGMP querier or not There should have the existing one and only one IGM...

Страница 47: ...is always unpredictable and the only basic assurance that can be offered is the best effort traffic delivery To overcome this challenge Quality of Service QoS is applied throughout the network This e...

Страница 48: ...SCP or Cos When select DSCP only trusted DSCP Differentiated Services Code Point values are mapped to a specific QoS class and drop precedence level DPL Frames with untrusted DSCP values are treated a...

Страница 49: ...cription Cos Value 0 7 User can assign each port a CoS value from 0 to 7 According to the IEEE 802 1p user can define each CoS value in 4 priority queues from Low to Normal Medium and High Click Apply...

Страница 50: ...he IP header The most significant 6 bits of the ToS field are fully decoded into 64 possibilities and the singular code that results is compared against the corresponding bit in the IPv4 ToS priority...

Страница 51: ...Mode Enable Port Mirroring function by check the box Go To Interface User can use the dropdown box to choose the destination port as Port to mirror on feature Monitor Direction User can select the mon...

Страница 52: ...k performance find and solve network problems and plan for network growth Network management systems learn of problems by receiving traps or change notices from network devices implementing SNMP 5 11...

Страница 53: ...nable SNMP Trap Enable SNMP Trap function by check the box Trap Destination IP User could insert the Server IP address as Trap Destination IP info Community User can release the SNMP to public for rea...

Страница 54: ...r to monitor the remote site network and device statuses 5 12 1 Syslog Setting The SYSLOG is a protocol to transmit event notification messages across networks Terms Value Description SYSLOG Mode Disa...

Страница 55: ...Apply button on the right bottom corner of the interface Then the system event logs will display within the SYSLOG LIST window The SYSLOG LIST will contain up to 5 pages of system event log informatio...

Страница 56: ...up the mail server IP address Sender E mail Address Set up the email account to send the alert Mail Subject The subject of the mail Authentication Check the box to enable the Authentication function U...

Страница 57: ...e same time After the event selection users can click the Apply button to save changes 5 12 5 Fault Alarm When any selected fault event has occurred the fault LED of the switch s front panel will ligh...

Страница 58: ...MAC address is to be forwarded through a given potential transmission port 5 13 1 MAC Address Table 5 13 2 MAC Table Configuration Users can check the checked box of each port and insert the port s VI...

Страница 59: ...test firmware from Antaira s website and store it within their local PC server or USB drive Terms Value Description FIRMWARE UPGRADE User can click the Choose File button to select the latest firmware...

Страница 60: ...vice through the built in USB port Users can use the USB port feature to execute the Auto Load function to boot the switch s configuration that has been saved within the USB storage device or users ca...

Страница 61: ...ms Value Description CONFIGURATION MANAGEMNET Backup Configuration By click the Backup button it allows user to backup the switch configuration setting to local PC or server Upload Configuration User...

Страница 62: ...f Upload If the folder or filename does not exist system will return error If it succeeds system will reboot Ex file1 folder file2 5 15 3 Auto Load Backup Terms Value Description USB Auto Load Select...

Страница 63: ...can use console or telnet to management switch by CLI CLI Management by RS 232 Serial Console 115200 8 none 1 none Before configuring by an RS 232 serial console use an RJ45 to DB9 F cable to connect...

Страница 64: ...Antaira Industrial Ethernet Switches LMP 0501 24 Series User Manual V1 1 58 Step 2 Input a name for the new connection Step 3 Select to use COM port number...

Страница 65: ...1 59 Step 4 The COM port property settings are as follows 115200 for Bits per second 8 for Data bits None for Parity 1 for Stop bits and none for Flow control Step 5 The Console login screen will appe...

Страница 66: ...is as below IP Address 192 168 1 254 Subnet Mask 255 255 255 0 Default Gateway none User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP addr...

Страница 67: ...nment temperature configure admin username admin configure admin password admin configure IP boot host dhcp configure ip address ip_addr ip_mask configure ip default gateway ip_router configure ip nam...

Страница 68: ...p sync month configure no ntp sync weekly configure show ntp client enable configure show ntp client timeserver configure show clock timezone configure show ntp sync schedule enable configure show ntp...

Страница 69: ...port tag qinq configure vlan group group_num group_portlist configure switchport pvid vlan_id interface switchport filter tagged untagged interface switchport provider interface switchport ethertype...

Страница 70: ...rt0 port1 g8032 no aps channel g8032 no revertive g8032 no port0 g8032 no port1 g8032 no ring id g8032 no timer hold off g8032 no timer guard g8032 no timer wtr g8032 show ethernet ring g8032 status g...

Страница 71: ...hello_time configure spanning tree max age max_age configure spanning tree cost link_cost_value interface spanning tree port priority port_priority interface spanning tree link type point to point po...

Страница 72: ...igure spanning tree mst instance_ID priority priority_number configure spanning tree mst instance_ID cost cost_value interface spanning tree mst instance_ID port priority priority interface no spannin...

Страница 73: ...ange configure show event smtp interface INTERFACE_NAME up down configure event syslog power1 enable configure event syslog power2 enable configure event syslog cold start enable configure event syslo...

Страница 74: ...er IP_address configure syslog mode both remote local configure no syslog server configure no syslog mode configure show syslog server configure show syslog mode configure show syslog log configure SM...

Страница 75: ...aes PWD configure no snmp server enable configure no snmp server community ro rw configure no snmp server v3 level admin user configure no snmp server v3 auth admin user configure no snmp server v3 e...

Страница 76: ...snmp trap version configure show snmp trap community configure show snmp trap inform retry configure show snmp trap inform timeout configure show snmp trap v3 user configure show snmp trap v3 level co...

Страница 77: ...nterface show qos default cos interface IGMP IGMP igmp snooping enable configure igmp snooping query max respond time second configure igmp snooping query interval second configure igmp snooping last...

Страница 78: ...SB 1 CLI enable configure terminal copy running config usb path Fill in the folder and filename behind the copy running config usb command Ex file1 folder file2 2 CLI enable configure terminal copy st...

Страница 79: ...igure terminal copy usb startup config path Fill in the folder and filename behind the copy usb startup config command Ex file1 folder file2 4 CLI enable configure terminal copy usb firmware path Fill...

Страница 80: ...Manual V1 1 74 5 CLI enable configure terminal Syslog mode usb or all Select USB or ALL it can auto save waning file to USB And the file name is message 6 CLI enable configure terminal usb auto load...

Страница 81: ...based Network Control Authentication IEEE 802 1ad Stacked VLAN Q in Q IEEE 802 1p QoS CoS Protocol for Traffic Prioritization Switch Protocol CSMA CD IGMPv1 v2 SNMPv1 v2 TFTP SNTP SMTP RARP Syslog Dat...

Страница 82: ...Power Connection 1 removable 6 contact terminal block PoE Power Output 30W per port Max Power Consumption 10 Watts no PD included 145 Watts Fully loaded Environmental Limits Operating Temperature STD...