background image

Antaira Technologies - Industrial PoE Injector 
INJ-C200G-bt-T - Hardware Manual - v1.0 

 

7. When all connections are set, the installation is complete. 

4.2 Maintenance and Service 

If the device requires servicing of any kind, the user is required to disconnect and remove it from 

its mounting. The initial installation should be done in a way that makes this as convenient as 

possible. 

Voltage / Power lines should be properly insulated as well as other cables. Be careful when 

handling them so as to not trip over. 

Do not under any circumstance insert foreign objects of any kind into the heat dissipation 

holes located in the different faces of the device. This may not only harm the internal layout 

but might cause harm to users as well. 

Do not under any circumstance open the device for any reason. Please contact your dealer 

for any repair needed or follow the instructions within the manual. 

Clean the device with a dry soft cloth. 

4.3 Troubleshooting 

Always verify the right power cord or adapter is being used. Never use a power supply or adapter 

with a non-compliant DC output voltage or it will burn the equipment. 

Select the proper UTP or STP cable in order to construct the network. Use an unshielded 

twisted-pair (UTP) or shield twisted-pair (STP) cable for RJ45 connections: 100Ω Category 5e for 

10/100Mbps. Also, be sure that the length of any twisted-pair connection does not exceed 100 

meters (328 feet). 

Diagnosing LED Indicators: To assist in identifying problems, the switch can be easily monitored 

with the LED indicators which help to identify if any problems exist. 

Please refer to the LED Indicators section for LED light indication. 

If the power indicator LED does not turn on when the power cord is plugged in, the user may have 

a problem with the power cord. Check for loose power connections, power losses, or surges at 

the power outlet. 

13 

Содержание INJ-C200G-bt-T

Страница 1: ...INJ C200G bt T Industrial Gigabit IEEE 802 3bt Type 4 4PPoE Injector EOT 40 C 75 C Hardware Manual Version 1 0 October 2020...

Страница 2: ...fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Antair...

Страница 3: ...tions radio si l quipement n est pas install et utilis conform ment aux instructions Cependant il n y a aucune garantie qu aucune interf rence ne se produira dans une installation particuli re Si cet...

Страница 4: ...tor Industrial Grade PoE Injector Hardware Manual Version 1 0 October 2020 The manual supports the following models INJ C200G bt T This document is the current official release hardware manual Please...

Страница 5: ...e Description 3 2 1 Physical Dimensions 3 2 2 Front View Panel 4 2 3 Top View Panel 5 2 4 LED Indicators 5 2 5 Ethernet Ports 5 2 6 Cabling 6 2 7 Wiring the Power Inputs 7 2 8 Grounding Note 8 3 Mount...

Страница 6: ...rature range of 40 C to 75 C making it ideal for outdoor or harsh industrial applications 1 1 Product Hardware Features System Interface and Performance Embedded 2 10 100 1000Tx RJ45 ports with 1 4PPo...

Страница 7: ...d alimentation Les sp cifications mat rielles les ports les informations de c blage et l installation du c blage de l injecteur PoE industriel seront d crits dans ce manuel du mat riel Warning Labels...

Страница 8: ...PoE Injector INJ C200G bt T Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 26mm x 75mm x 95mm F...

Страница 9: ...igure 2 2 below shows the front panel of the product series Figure 2 2 Front View Panel WARNING Airflow around the switch must be unrestricted To prevent the switch from overheating there must be the...

Страница 10: ...ow in Table 2 1 LED Color Description Power Green On Power Input 1or 2 or both is active Off Power Input 1 and 2 is inactive PoE Green On The port is supplying power to the powered device Off No power...

Страница 11: ...l Pin Number Signal Pin Number Signal Pin Number Signal 1 TP0 3 TP1 1 TP0 1 TP1 2 TP0 6 TP1 2 TP0 2 TP1 3 TP1 1 TP0 3 TP1 3 TP0 4 TP2 7 TP3 4 TP2 4 TP3 5 TP2 8 TP3 5 TP2 5 TP3 6 TP1 2 TP0 6 TP1 6 TP0...

Страница 12: ...V1 V1 and PWR2 V2 V2 contacts on the terminal block connector as shown below in Figure 2 6 Figure 2 6 Power Terminal Block 2 Tighten the wire clamp screws to prevent the wires from loosening as shown...

Страница 13: ...ic Interference EMI Run the ground connection from the ground screw to the grounding surface before connecting devices The grounding screw symbol is shown below in Figure 2 9 Figure 2 9 Grounding Scre...

Страница 14: ...ide of the industrial PoE injector Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To remove t...

Страница 15: ...industriel 1 Remove the DIN Rail bracket from the industrial PoE injector by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial PoE injector 3 Use the scr...

Страница 16: ...dustrial PoE Injector INJ C200G bt T Hardware Manual v1 0 Figure 3 4 Remove DIN Rail bracket from the Switch Below in Figure 3 5 are the dimensions of the wall mounting bracket Figure 3 5 Wall Mountin...

Страница 17: ...If the DIN Rail is not screwed on the industrial PoE injector please refer to the DIN Rail Mounting section for DIN Rail installation If it is required to wall mount the industrial PoE injector please...

Страница 18: ...r any repair needed or follow the instructions within the manual Clean the device with a dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter is being used Never use a powe...

Страница 19: ...se contact Antaira for technical support service if the problem still cannot be resolved If the industrial switch LED indicators are normal and the connected cables are correct but the packets still c...

Страница 20: ...Base T Fast Ethernet 1 488 000pps for Gigabit Ethernet Port Interface Ethernet Port 2 10 100 1000Base T X with 1 4PPoE 97W Port PoE Pin Assignment V for pin 3 4 5 6 V for pin 1 2 7 8 LED Indicators Sy...

Страница 21: ...00 4 2 3 4 5 6 8 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Compliant Certifications FCC CE Warranty 5 Years Table 5 1 Technical Specifications Antaira Customer Serv...