5. Installing the Converter
Please follow these steps to install the PoE Media converter:
● Turn off the power of the device/station on the network to
which the FCU-1802Px will be attached.
● Ensure that there is no activity in the network.
● Attach fiber cable from the FCU-1802Px to the fiber network.
TX, RX must be paired at both ends.
● Attach a Cat. 5 UTP cable from the 10/100Base-TX network to
the RJ-45 port on the FCU-1802Px.
● Connect the 48V DC power adapter to the FCU-1802Px and
verify that the Power LED is lit.
● Turn on the power of the device/station, the TX Link and FX
Link LEDs should light when all cables are attached.
FCU-1802Px
10/100Base-TX
Cat. 5/5e TP
Cable Network
100Base-FX Fiber
Network
TX
TX
RX
RX
Note
● RJ-45/STP, UTP Cat 5, straight /crossover cable
is accepted.
● Please refer to section 9 for more about the
wiring distance of your TP, Optic-fiber networks.