PN:6306X2312300XXX
4. LED Description
LED
Color
Function
Power
Green
Lit when power is available
TX/Link
ACT
Green
Lit when TP cable connection with
remote device is good
FX/Link
ACT
Green
Lit when Fiber cable connection with
remote device is good
FDX/COL
Green
Lit when TP works in Full Duplex
mode
Status
Green
Lit when Local or Remote Fiber
Link is O.K.
Blinking when testing success
Orange
Lit under below condition:
Remote/ Local FX/TX port link down
Connect device not 2312 series
Blinking when testing failure
10/100M
Green
Lit when TP link in 100M
5. Technical Specifications
Standards :
IEEE 802.3, 802.3u
Interface:
1 X RJ45 connector
1 X SC Duplex connector
Diagnostic LED:
Power, TX/Link ACT, FX/Link ACT
FDX/COL, Status, Speed
Power Consumption
3.5W
Shipping Weight
1LB
Dimensions:
119mm
×
86mm
×
25 mm(W x D x H)
Temperature
: Operating: 0 ~ 50
o
C
Storage: -20 ~ 60
o
C
Humidity:
5% ~ 90% RH
Emission:
EMI: FCC/CE Class A
UTP
Cat. 5 UTP cable
Fiber
8.3/125, 8.7/125, 9/125 or 10/125
µ
m single-mode
6. DIP Switch
Pin 1 Off/On TP Auto-negotiation Disable/Enable
Pin 2 Off/On TP Speed 10M/100M
Pin 3 Off/On TP Duplex Half /Full
Pin 4 Off/On Flow control Disable/Enable
Pin 5 Off/On MDIX/MDI mode Force/Auto
Pin 6 Off/On MDI/MDIX
Note: Pin 5 is mutually exclusive to Pin 6, when Pin 5 is
set to OFF, Pin 6 can manually set MDI/MDIX to ON/OFF.
If Pin 5 is set to ON (auto mode) then disregard Pin 6.
Default Setting
Pin1
Pin2
Pin3
Pin4
Pin5
Pin6
On
On
On
On
On
On
Please perform Power On reset after modify the Dip
Switch setting and firmware update
FCM-2312WX
10/100Base-TX to 100Base-FX
Smart Diagnostic
WDM Converter
User’s Guide
v1.2