ANSMANN ENERGY 16 Скачать руководство пользователя страница 5

GB

 

OpERatiNG iNstRuctiONs ENERGY 16

usE OF thE chaRGER

Charger  with  automatic  refreshing  function  for  1-12  Micro  AAA  or    Mignon  AA  cells, 

for  1-6  Baby  C  or    Mono  D  cells  in  addition  to  1-4  pcs.  9  V  blocks.  NiCd  and  NiMH 

rechargeable batteries can be charged at the same time.

FEatuREs

Capacity  quick  test  for  the  inserted  cells  for  approx.  5  sec.;  Auto  diagnosis  of  the 

inserted  cells  as  soon  as  contact  is  made;  Automatic  start  of  a  refreshing  programme 

at the beginning of the charging process when tired cells are detected; NiCd and NiMH 

rechargeable  cells  can  be  inserted  and  charged  at  the  same  time;  Microprocessor 

controlled charging and supervision of the charging status of  cylindrical cells and 9 V 

blocks; Individual microcontrolled supervision of the charging status for each cell during 

the complete charging time; Individual supervision of every cell position; -delta V control 

of each cell; Faulty cell detection – damaged cells are identified and displayed; Automatic 

switch-over to trickle charge; Clear colour indicators of the rechargeable battery status for 

each charging position; Switch mode power supply for worldwide use  (100-240 V AC)

BattERY quick tEst

After inserting the cells the state of the charge is displayed.

LED green:    capacity over 80% of the nominal capacity

LED yellow:   capacity between 25 and 80% of the nominal capacity

LED red: 

capacity under 25% of the nominal capacity

After  5  sec.  if  the  cells  are  not  removed,    the  unit  switches  over  to  autom.  refreshing-

/charge mode.

lEd iNdicatORs

LED flashes red/green „Refreshing“: refresh mode 

LED  lights  red  „Charging“:  charging  process

LED  lights  green  „Ready“:  battery 

fully charged / trickle charge

LED  flashes  red  „Error“:  faulty  cell 

detected

The charging status of the rechargeable batteries are supervised by the microcontroller in 

regular intervals. 

OpERatiON

Connect the charger to the mains supply (100–240 V AC 50-60 Hz). After inserting the 

rechargeable batteries the state of charge is displayed. Then the charge-/ refresh process 

starts  for  every  charging  circuit  separately.  The  charging/refreshing  process  starts  for 

each charging circuit separately as soon as one or several cells are inserted. To insert a 

cylindrical cell move the silver contact bridge backwards and put in the rechargeable cell 

at the bottom of the charging slot. Please pay attention to the correct polarity (the positive 

pole of the cells must point towards the LED indicators). The charger is equipped with 6 

dual slots  for cylindrical cells. In each charging position you can either insert 2 pcs. of 

Micro  AAA  or  Mignon  AA  cells  or  1  pce.  of  Baby  C  or  Mono  D  cells.  When  inserting 

Baby C or Mono D cells both contact bridges must fit closely on the battery and the cells 

must be located centrally. The left indicator of the dual charging slot signals the charging 

process. A certain amount of heating of the rechargeable cells during charging is normal. 

If required the unit starts refreshing and switches over automatically to charging. As soon 

Содержание ENERGY 16

Страница 1: ...Westfalia Bedienungsanleitung Nr 109950 ...

Страница 2: ... Operating Instructions F Manuel d utilisation I Manuale d istruzione E Instrucciones de manejo NL Gebruiksaanwijzing FIN Käyttöohje S Instruktionsmanual P MANUAL DE INSTRUÇÕES PL Zastosowanie H Használati utasítás SK Návod na použitie ...

Страница 3: ... gelb Kapazität zwischen 25 und 80 der Nennkapazität Anzeige rot Kapazität unter 25 der Nennkapazität Nach 5 Sekunden erfolgt die Umschaltung auf den automatischen Refreshing Lademodus falls der jeweilige Akku nicht aus dem Gerät genommen wird Leucht Anzeigen Anzeige blinkt rot grün Refreshing Refreshing Programm Anzeige leuchtet rot Charging Ladevorgang Anzeige leuchtet grün Ready Akku geladen Im...

Страница 4: ...uses oder des Netzkabels nicht in Betrieb nehmen Gerät nicht öffnen Reparaturen dürfen nur durch den autorisierten Fachhandel vorgenommen werden Wartung uND Pflege Um eine einwandfreie Funktion des Gerätes sicherzustellen halten Sie bitte die Kontakte in den Ladeschalen frei von Verschmutzungen Reinigung des Gerätes nur bei gezogenem Netzstecker und mit einem trockenen Tuch vornehmen Garantie Soll...

Страница 5: ...pacity After 5 sec if the cells are not removed the unit switches over to autom refreshing charge mode LED indicators LED flashes red green Refreshing refresh mode LED lights red Charging charging process LED lights green Ready battery fully charged trickle charge LED flashes red Error faulty cell detected The charging status of the rechargeable batteries are supervised by the microcontroller in r...

Страница 6: ...tteries or other types could cause an explosion Do not plug in the charger if there are any signs of damage to the housing or power cable Never try to open the charger Repairs may only be made by authorised service centres Maintenance and cleaning To make sure that the charger works properly please keep the contacts in the charging slots free from dust or contamination To clean the unit disconnect...

Отзывы: