15
CHARGING CURRENT
Note:
The maximum charging current per charging compartment
depends on the number of occupied compartments.
Occupied charging
compartments
Max. charging current per compartment
1-2
2000 mA
3
1500 mA
4
1000 mA
Note:
We recommend charging rechargeable batteries with a charging
current of 500/1000 mA if there is enough time. This will prevent
excessive heating and protect the battery.
Caution:
As a general rule: The charging current value may not exceed
the battery capacity value.
Example:
Battery capacity 1400 mAh - Charging current 1000 mA
MODES
CHARGE
Charge rechargeable battery.
Once the rechargeable battery is fully
charged, the display
will show the END indicator.
DISCHARGE
Discharge rechargeable battery.
Once the rechargeable battery is
discharged, the display
will show the END indicator.
Note:
The discharging current is limited to 500 mA.
TEST
Measure rechargeable battery capacity and then charge (charge
- discharge - charge).
Once the rechargeable battery is charged
the second time, the display
will show the END indicator
. The
measurement is complete and the battery fully charged.
Note:
You can select the charging current for the charging process.
Measured value:
The charge flow is measured during discharging only.
The
mAh indicator
shows the rechargeable battery’s
capacity value
.