if the main set received the alarm signals from detectors, it will alarm if set no delay time,but 

if  you  set  a delay  time  for guard,for  example 30  seconds,  setting  guard  will  take  into  effect 

only after 30 seconds later from the  time  you pressed the 

       

key. This  delay  time can be 

normally left for you to prepare to exit your house entry. 

 

Fig.2 Setting panel illustration 

 

Fig.3 Remote controller illustration 

 

*withdraw guard setting by remote controller:

 

      Press and release 

       

  key on the remote controller, the “GUARD”LED on the main set 

will  go  out  ,the  main  set  went  into  status  of  withdraw  guard.  At  this  time,  if  the  main  set 

received the alarm signals from all detectors of zone 1,2,3,4, it will not alarm. 

 

2.

 

setting guard by pressing keypad on the main set 

         

*Setting guard on the keypad: 

   

When not in alarm state,press four digits user password consecutively (for example: “1234”, 

ect),then press key “set” ,then press digit “ 9”, the “GUARD” LED on the main set will light 

up  ,the  main  set  went  into  status  of  setting  guard.  At  this  time  if  the  main  set  received  the 

alarm  signals  from  detectors,  it  will  alarm  at  once  or  delayed  for  a  period  of  option 

time(0~90s), 

 

* withdraw guard on the keypad 

           

    Press four digits user password consecutively, then press key set,then press digit 0, the main 

set went into withdraw guard, in this state, if the main set received the alarm intruder signal 

from the detectors , it will not alarm , but if it received trigger signal from the panic button of 

the remote controller, it will alarm and dial out telephone numbers automatically. 

 

3.

 

Open or close a guard zone alarm 

 

Each of the four guard zone can be opened or closed, if a guard zone is closed, the main 

set  will  not report out  alarm  signal  from  the  guard  zone  received.For  example  ,if  a  PIR 

detector or door contacts is set belong to guard zone 3,when this detector emit signal to 

the alarm main set, the main set zone 3 will not report signal out even in guard state,but 

other detectors belong to other zones will be working as usual.. 

 

*

withdraw guard setting:

 

    When  not  in  alarm  state,  press  four  digits  user  password  consecutively  (for  example: 

“1234”, ect),then press key “set” ,then press digit “ 0 ”, the “GUARD” LED on the main set 

will  go  out  ,the  main  set  went  into  status  of  withdraw  guard.  At  this  time  if  the  main  set 

received the alarm signals from detectors of zone 1,2,3,4,, it will not alarm. 

  When in alarm state,simply press four digits user password on the keypad will cancel guard 

Содержание AST-2008D2

Страница 1: ...troller which will make the main dialer give out loud sound or not as well as dialing when being trigged 14 Convenient key input is prepared on the front panel Various kinds of door magnetic switch an...

Страница 2: ...od of option time 0 90s withdraw guard on the keypad Press four digits user password consecutively then press key set then press digit 0 the main set went into withdraw guard in this state if the main...

Страница 3: ...t then press set 2 Open guard zone 2 press four digit password first then press set 3 Close guard zone 2 press four digit password first then press set 4 Open guard zone 3 press four digit password fi...

Страница 4: ...hen you press key store group number 1 6 store For example if you want to delete second group telephone numbers press key four digit password such as 1234 or other at first then you press key store th...

Страница 5: ...a period of time 0 90seconds and then report alarm the initial value is zero no delay 10 Open telephone line cut off detect fuction Press key four user digit password such as 1234 or other at first th...

Страница 6: ...ur callee telephone alarm receive telephone not more than 20 seconds interval If you don t withdraw guard when you received the alarm the alarm set will dial the pre stored next group telephone number...

Страница 7: ...ner of the room is preferable and its detecting direction prependicular to people walking direction will have best effect Mounting method take out the bracket in the accessories and fix it on your wal...

Страница 8: ...nd 4 bit zone code Fig 4 buit in circuit of infrared detector You can also open the emmiter part of the door entry contacts there are also 36 metal pins on the side of the electronic circuit board thi...

Страница 9: ...ne 3 Fig 17 the 8 bit address code in the middle row is set as 22212011 the zone code is 2112 zone 3 Fig 18 the 8 bit address code in the middle row is set as 11011220 the zone code is 2111 zone 4 Zon...

Страница 10: ...you withdraw guard Fig 20 illustraton diagram of R Femitting module encoding A wireless emergency button is generally configured as 24 hours guard zone in the same method Fig 21 illustration diagram...

Отзывы: