USER MANUAL 

MAIN    FUNCTION    AND    FEATURES

 

1.

 

DC 9V power supply, standby current less than 20mA 

2.

 

Six groups of alarm telephone numbers can be pre-stored 

3.

 

Ten seconds pre-recorded memo messages 

4.

 

Long distance  via public  telephone  network  set  guard  status  or  withdraw  guard  to  the  main 

dialer 

5.

 

Long  distance  via  public  telephone  network  monitor  the  background  sound  around  the 

auto-dialer 

6.

 

Setting guard delay time 0~90 seconds for four guard zone   

7.

 

Setting alarm delay time 0~90 seconds for four guard zone alarm signal 

8.

 

Siren hooting time length control option 1~20 minutes 

9.

 

Telephone line cut off alarm function option 

10.

 

Six wireless distinguishable guard zones LED indicator on the main set 

11.

 

Each of the four guard zones can be set on guard or withdraw guard independently 

12.

 

One panic key for help provided on the main set   

13.

 

Two panic keys for help is provided on the remote controller which will make the main dialer 

give out loud sound or not as well as dialing when being trigged 

14.

 

Convenient key input is prepared on the front panel 

 

 

 

Various  kinds  of  door  magnetic  switch  and  PIR  infrared  detector  are  configurable. 

Rechargeable DC9V power transformer provided for power cut backup.The dialer can report 

the  alarm  messages  to  an  administration  computer  immediately  via  the  public  telephone 

network..   

 

 

OPERATION METHOD 

Fig.1 System connection illustration 

     

Note:the extension can connected to your telephone machine 

 

Set guard and withdraw guard 

  This  alarm  system  can  be  divided  into  four  alarm  guard  zones.  Each  guard  zone  can 

configured  with  several  door  entry  detectors,  infrared  detectors,  gas  leakage  detectors  and 

smoke  detectors.  You  can  set  guard  or  withdraw  guard  using  the  remote  controller  or  by 

pressing the keypay on the main set. 

 

1.

 

Setting guard by using remote controller   

*Setting guard: 

    Press and release   

   

key on the remote controller, the ‘  GUARD”  LED  on  the  main  set 

will light up ,buzzer beep one time ,the main set went into status of setting guard. At this time, 

Содержание AST-2008D2

Страница 1: ...troller which will make the main dialer give out loud sound or not as well as dialing when being trigged 14 Convenient key input is prepared on the front panel Various kinds of door magnetic switch an...

Страница 2: ...od of option time 0 90s withdraw guard on the keypad Press four digits user password consecutively then press key set then press digit 0 the main set went into withdraw guard in this state if the main...

Страница 3: ...t then press set 2 Open guard zone 2 press four digit password first then press set 3 Close guard zone 2 press four digit password first then press set 4 Open guard zone 3 press four digit password fi...

Страница 4: ...hen you press key store group number 1 6 store For example if you want to delete second group telephone numbers press key four digit password such as 1234 or other at first then you press key store th...

Страница 5: ...a period of time 0 90seconds and then report alarm the initial value is zero no delay 10 Open telephone line cut off detect fuction Press key four user digit password such as 1234 or other at first th...

Страница 6: ...ur callee telephone alarm receive telephone not more than 20 seconds interval If you don t withdraw guard when you received the alarm the alarm set will dial the pre stored next group telephone number...

Страница 7: ...ner of the room is preferable and its detecting direction prependicular to people walking direction will have best effect Mounting method take out the bracket in the accessories and fix it on your wal...

Страница 8: ...nd 4 bit zone code Fig 4 buit in circuit of infrared detector You can also open the emmiter part of the door entry contacts there are also 36 metal pins on the side of the electronic circuit board thi...

Страница 9: ...ne 3 Fig 17 the 8 bit address code in the middle row is set as 22212011 the zone code is 2112 zone 3 Fig 18 the 8 bit address code in the middle row is set as 11011220 the zone code is 2111 zone 4 Zon...

Страница 10: ...you withdraw guard Fig 20 illustraton diagram of R Femitting module encoding A wireless emergency button is generally configured as 24 hours guard zone in the same method Fig 21 illustration diagram...