12

Maintenance

Inspection

Garments must be inspected upon delivery and before and after each use. Use the 
following guidelines when inspecting:

• Visually inspect the garments both inside and outside.
• Look for surface damage or tears on material and seams.
• Check the function of the zipper.

If the garment has been subjected to contaminants, it should be decontaminated prior to 
laundering, re-use or storage. If any damage/malfunction is found, the garment must be 
taken out of service. Do not attempt to repair.

Decontamination and Cleaning

AlphaTec

®

 chemical protective garments require proper care to ensure performance. 

Do not use clothing items that are not thoroughly cleaned and dried.

After contact with chemicals the garment should be decontaminated with a suitable 
decontamination solution prior to laundering.

Cleaning and laundering recommendations are as follows:

• Machine wash using powdered laundry detergent in warm water (<105°F or 41°C), rinse 

thoroughly.

• Maximum 25 washing cycles for orange hi-visibility garments.
• For best results, hang to dry. However, garments can be tumbled dried using cotton 

setting. High temperatures can separate the seam tape.

• DO NOT use liquid bleach, starch or fabric softener.
• DO NOT dry clean.
• DO NOT press or iron.
• DO NOT scrape or scrub the fabric, which could compromise its chemical resistance.
• If the garment is stained by grease or oil, a spray pre-wash can be used on the stains prior 

to laundering.

• If the hook and loop fasteners become contaminated with lint, brush the hooks carefully 

with a suitable small brush to remove.

Marking

Marking on the garment can be made by a “permanent marker” type of pen, however the 

ink may bleed.

Содержание AlphaTec 66-600 Series

Страница 1: ...66 600 Breathable Chemical Protective Clothing Instructions for Use AlphaTec 66 600 Series This manual may only be removed from the garment by the end user...

Страница 2: ......

Страница 3: ...of Use 7 Pre use 8 Sizes 8 Recommended Undergarments 8 Donning and Doffing 9 Donning Procedure 9 Doffing Procedure 10 Storage 11 Storage Conditions 11 Storage Methods 11 Storage Life Shelf Life 11 Mai...

Страница 4: ...cal Response Choosing the appropriate chemical protective clothing accessories and other necessary equipment to deal with a chemical exposure or chemical emergency has to be made by qualified safety p...

Страница 5: ...emical protection see Decontamination and Cleaning section Multiple fabric options to address different working environments and risks Garment Material AlphaTec 66 600 Series garments are constructed...

Страница 6: ...Category 2 as defined by NFPA 70E They have been tested by an independent laboratory based on ASTM F1891 02 ASTM 1959 05 Standard Test Method for Determining Arc Thermal Performance of Textile Materia...

Страница 7: ...re ranges from 40 F to 150 F 40 C to 65 C Never use the garment near open flames or intense heat Only the blue Nomex version is suitable for use where heat or arc flash might be anticipated WARNING Th...

Страница 8: ...g S 62 64 157 163 90 130 41 59 M 64 66 163 168 130 170 59 77 L 66 69 168 175 170 210 77 95 XL 69 71 175 180 210 235 95 107 2XL 71 74 180 188 235 260 107 118 3XL 74 76 188 193 260 290 118 132 Recommend...

Страница 9: ...er the boots and secure the hook and loop closures on the legs of the garment For bib overalls secure shoulder straps Adjust buckles for a comfortable fit and don jacket For coveralls jackets and coat...

Страница 10: ...oop closures and the zipper and remove arms from coverall jacket or coat one at a time Once arms are free have assistant hold or lift the garment away from the wearer avoiding any contact between the...

Страница 11: ...nd dry prior to storage Store in a dry environment out of direct sunlight Keep away from ozone generating sources for example electrical engines fluorescent lamps and air conditioners Storage Methods...

Страница 12: ...d be decontaminated with a suitable decontamination solution prior to laundering Cleaning and laundering recommendations are as follows Machine wash using powdered laundry detergent in warm water 105...

Страница 13: ...the garment must be taken out of service Garments that are not completely decontaminated must be disposed of in a safe manner taking local regulations for the specific chemical into account Garments...

Страница 14: ...tion Pass Overall garment function and integrity ASTM F1154 Section 8 3 Complete all tasks within 15 minutes Pass No liquid penetration Pass Accommodates head protection devices meeting ANSI ISEA Z89...

Страница 15: ...ation resistance test ASTM F903 Section 8 4 No penetration for at least 1 hour for each of the speci fied chemicals See separate table Seam breaking strength ASTM D751 Section 8 8 Strength 33 N 25 mm...

Страница 16: ...e test ASTM F903 Section 8 4 No penetration for at least 1 hour for each of the speci fied chemicals See separate table Seam breaking strength ASTM D751 Section 8 8 Strength 33 N 25 mm 186 N 25 mm Gar...

Страница 17: ...dium hypochlorite 10 Pass Pass Pass Sulfuric acid CAS No 7664 93 9 93 1 Pass Pass Pass Pass Pass Tetrachloroethylene CAS No 127 18 4 95 Pass Pass Pass Note Shaded areas indicate no requirement for tes...

Страница 18: ...18...

Страница 19: ......

Страница 20: ...AM and Tenara are trademarks owned by W L Gore Associates Inc NOMEX is a registered trademark owned by E I Du Pont de Nemours and Company 2018 Ansell Limited All Rights Reserved A N S E L L 1 8 0 8 An...

Отзывы: