Страница 1: ...r 36585K Precision AutoCal 70 kHz to 40 GHz 2 port 36585V Precision AutoCal 70 kHz to 70 GHz 2 port Part Number 10410 00279 Revision C Published April 2015 Copyright 2015 Anritsu Company Anritsu Compa...

Страница 2: ...LITY FOR CONSEQUENTIAL DAMAGES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL ANRITSU COMPANY OR ITS SUPPLIERS BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAG...

Страница 3: ......

Страница 4: ...h a degree that they cannot be unlawfully used for military purposes CE Conformity Marking Anritsu affixes the CE Conformity marking onto its conforming products in accordance with Council Directives...

Страница 5: ...European Parliament and Council Directive 2002 96 EC Chinese RoHS Compliance Statement...

Страница 6: ......

Страница 7: ...nts 1 2 Chapter 2 Maintenance Instructions 2 1 Inspecting Connectors 2 1 2 2 Cleaning Connectors 2 1 2 3 Making the Connection 2 2 Torque Specifications and Tools 2 2 2 4 Measuring Pin Depth 2 3 Pin D...

Страница 8: ...Contents 2 PN 10410 00279 Rev C 36585K 36585V RM...

Страница 9: ...surement AutoCal has been characterized by Anritsu and the characterization file is included for use by the host VNA It is valid for 1 year from time of shipment The characterization cycle for the 365...

Страница 10: ...ow Index Description 1 01 201 torque wrench 8 mm 0 9 N m 2 Characterization data on a USB memory device 3 36585 precision AutoCal 4 01 204 universal wrench for K and V connectors Additional included i...

Страница 11: ...00279 Rev C 2 1 Chapter 2 Maintenance Instructions This chapter provides instructions on the care and use of precision connectors It includes information on inspection cleaning pin depth measurement...

Страница 12: ...n dry compressed air 2 Apply a small amount of Isopropyl Alcohol IPA to a lint free cotton swab 3 Rotate the cotton swab around the connector avoiding lateral pressure 4 Blow out any remaining debris...

Страница 13: ...nectors together Finger tighten the connection first by turning the connector nut Do not turn the connector body The final tightening is done using the appropriate torque wrench set to the correct tor...

Страница 14: ...in depth is measured from a connector reference plane to a defined point on the connector center pin depending on the connector type A typical example of pin depth dimensions for a male and female con...

Страница 15: ...uge coupling nut and adapters will vary depending on the connector type Checking the Gauge Pin depth gauges should be checked for cleanliness before each use Follow the connector cleaning procedure to...

Страница 16: ...To measure V female connectors screw the male adapter onto the gauge coupling nut 6 Tolerance Gauge Settings Tolerance Gauge Settings Refer to Table 2 2 below When gaging pin depth if the test device...

Страница 17: ...Maintenance Instructions 2 4 Measuring Pin Depth 36585K 36585V RM PN 10410 00279 Rev C 2 7...

Страница 18: ...Anritsu utilizes recycled paper and environmentally conscious inks and toner Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com...