background image

QSG-6

Connecting the Hardware

QSG-8

PN: 10580-00470  Rev. B

Mapper QSG

Connecting the Wireless Travel Router

The wireless travel router connects to the MS27101A.

1. 

Refer to 

Figure QSG-9

.

2. 

Connect the LAN Ethernet and USB type A cables to the wireless travel router.

3. 

Connect the wireless travel router USB Type A cable to the USB Type A port on the MS27101A.

4. 

Connect the wireless travel router LAN Ethernet cable to the Ethernet port on the MS27101A. 

Powering On the In-Building Coverage Mapper

1. 

Disconnect the SM7005 cable from the SM7004 front panel if connected.

2. 

Set the SM7004 voltage to 12 VDC to operate the MS27101A as described in 

“Setting the SM7004 

Voltage” on page QSG-4

.

3. 

Connect the SM7005 cable to the SM7004 front panel DC In jack. 

4. 

Power on the MS27101A. After a few seconds, the green LED on the wireless travel router will power on. 
This confirms that the MS27101A and the wireless travel router are communicating properly. The 
In-Building Coverage mapper is now powered on.

1. Wireless Travel Router

2. MS27101A

Figure QSG-9.

Ethernet and USB Cable Connection

1

LAN Ethernet

USB Type A

2

Содержание MS27101A-IBCM

Страница 1: ...ive Morgan Hill CA 95037 2809 USA http www anritsu com Part Number 10580 00470 Revision B Published November 2020 Copyright 2020 Anritsu Company Quick Start Guide MS27101A IBCM In Building Coverage Ma...

Страница 2: ...eproduced copied or used in whole or in part as the basis for manufacture or sale of the equipment or software programs without the prior written consent of Anritsu Company Export Management The Anrit...

Страница 3: ...NEON Signal Mapper User Guide PN 10580 00422 can be found on the product page https www anritsu com en us test measurement products ma8100a For additional information and literature covering your pro...

Страница 4: ...MS27101A Type N Torque The antenna Type N connector types and the recommended torque specs are listed in Table QSG 2 1 Power Switch 2 Ethernet Port 3 USB Type A Port 2 4 RF Input Type N Torque specs...

Страница 5: ...nel is shown below in Figure QSG 2 SM7004 Omni Power Bank The SM7004 is the power source for the MS27101A The SM7004 front panel is shown in Figure QSG 3 1 Powered On Indicator LED 2 USB Type A Port 3...

Страница 6: ...attery is not fully charged and will need to be charged before continuing 2 Set the SM7004 to DC output mode by double pressing the power button 3 In DC output mode set to 12 VDC by single pressing th...

Страница 7: ...09 foam enclosure for performing the In Building Coverage Mapping as shown in Figure QSG 5 Ensure the MS27101A and SM7004 fit flush into the SM7009 foam slots as shown in Figure QSG 6 1 SM7004 2 SM700...

Страница 8: ...equipment interface connections are described in this section Connect the SM7004 The MS27101A rear panel battery jack is accessible through the foam cutout as shown in Figure QSG 7 1 MS27101A Rear Pa...

Страница 9: ...parate the foam side piece from the main battery foam enclosure to form a groove as shown in Figure QSG 8 3 Route the SM7005 through the groove 4 Insert the entire foam enclosure assembly consisting o...

Страница 10: ...Powering On the In Building Coverage Mapper 1 Disconnect the SM7005 cable from the SM7004 front panel if connected 2 Set the SM7004 voltage to 12 VDC to operate the MS27101A as described in Setting th...

Страница 11: ...alling Software Download and install the MA8100A In building Coverage Mapping with TRX NEON Signal Mapper software at https www anritsu com en us test measurement products ma8100a Powering Off the In...

Страница 12: ...Anritsu utilizes recycled paper and environmentally conscious inks and toner Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com...