2-1 Front Panel

Front and Rear Panel Connections

2-2

PN: 10410-00783  Rev. A

MN25131A OM

6

+12 V

+12 Volt Supply

- Four output connections.

- LED is Green when connector is inserted in any of the four.

- LED will turn orange when > 3.7A is drawn from the supply.

- LED will extinguish when > 4.0 A are drawn.

7

USB 3.0 HUB

- Six USB 3.0 Connections.

- Hub input on rear of extender.

- Each connector has an LED indicator that shows of activity present.

Table 2-1.

MN25131A Front Panel Connectors (2 of 2)

Ref

Name

Function

Содержание MN25131A Series

Страница 1: ...Series Multi Function Extender Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com Part Number 10410 00783 Revision A Published July 2020 Copyright 2020 Anritsu Compan...

Страница 2: ...Front 2 PN 10410 00783 Rev A MN25131A OM...

Страница 3: ...nel 2 3 Chapter 3 Performance Considerations 3 1 Power Connection 3 1 3 2 Battery Operation 3 1 3 3 Battery Removal 3 2 3 4 Supply Overload Protection 3 2 SFP Fiber Optic Transceiver Care and Removal...

Страница 4: ...Contents 2 PN 10410 00783 Rev A MN25131A OM...

Страница 5: ...ing measurement instruments in locations that are not necessarily close to AC line power One 5 V four 12 V and one 20 V supply connections are available The inclusion of a six port USB HUB allows the...

Страница 6: ...Introduction 1 2 PN 10410 00783 Rev A MN25131A OM Figure 1 2 The MN25131A modules play a key role in supporting the two 25 meter MS46131As in the ME7868A Modular 2 Port Network Analyzer System...

Страница 7: ...BATTERY STATUS Four LEDS show internal battery charge status 25 range for each LED For example if 50 LED is on then battery is charged from 26 to 49 25 LED will turn Orange if charge is 10 25 LED wil...

Страница 8: ...when connector is inserted in any of the four LED will turn orange when 3 7A is drawn from the supply LED will extinguish when 4 0 A are drawn 7 USB 3 0 HUB Six USB 3 0 Connections Hub input on rear o...

Страница 9: ...ical Fiber Converters on page 3 4 2 FIBER EXTENDER USB Type B to SFP Optical Fiber Converter S and R LEDs indicate Activity on the Fiber Outputs 3 FIBER EXTENDER USB Type B to SFP Optical Fiber Conver...

Страница 10: ...2 2 Rear Panel Front and Rear Panel Connections 2 4 PN 10410 00783 Rev A MN25131A OM...

Страница 11: ...pin grounded power outlet connected in turn to local AC Mains If a grounded 3 pin outlet is not available use a conversion adapter and ground the green wire or connect the equipment frame to a suitabl...

Страница 12: ...y door 3 Pull straight out on the lanyard to remove the battery pack from the unit 3 4 Supply Overload Protection The battery will disconnect the outputs when the load current exceeds 8 amps for 6 sec...

Страница 13: ...he front panel of the MN25131A are a USB 3 0 Hub The 6 port Hub appears as two USB 2 0 Hubs and two USB 3 0 hubs on the PC device manager It can control any USB 1 0 2 0 High Speed USB 2 0 Super Speed...

Страница 14: ...communications between MN25131A extenders used in long distance ME7868A installations They consist of either USB A or USB B 2 0 connectors which are converted to LC Duplex drivers The USB 2 0 connect...

Страница 15: ...Max current at 15 VDC Battery Lithium Ion 11 1V 8 4 Ah 94 Wh capacity Supply Outputs 20 V 5 V 12 V 19 5 20 4 VDC 2 5 Amps Max 4 9 5 1 VDC 2 5 Amps Max 11 7 12 25 VDC 4 0 Amps Max between the four con...

Страница 16: ...ew Zealand RCM AS N25 4417 2012 South Korea KCC REM A21 0004 Table 4 4 MIL PRF 28800F Class 2 Environmental Specifications Operating Temperature Range 10 C to 55 C Storage Temperature Range 51 C to 71...

Страница 17: ......

Страница 18: ...Anritsu utilizes recycled paper and environmentally conscious inks and toner Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com...

Отзывы: