A-4 Functional Listings
MG369xC GPIB PM
PN: 10370-10374 Rev. F
A-15
A-4
Functional Listings
Table A-2.
Configuration GPIB Command List
Command Code
Function
Page
BPN
Selects -3.3V for retrace and bandswitch blanking outputs.
BPP
S3.3V for retrace and bandswitch blanking outputs.
EBW0
Selects the external reference loop bandwidth of 10 Hz.
EBW1
Selects the external reference loop bandwidth of 30 Hz.
EBW2
Selects the external reference loop bandwidth of 100 Hz.
EBW3
Selects the external reference loop bandwidth of 300 Hz.
FRS
Opens the frequency scaling reference multiplier parameter.
RC0
Selects RF to be off during frequency switching in CW, step sweep,
and list sweep modes.
RC1
Selects RF to be on during frequency switching in CW, step sweep,
and list sweep modes.
RO0
Selects RF to be on at reset.
RO1
Selects RF to be off at reset.
RT0
Selects RF to be off during retrace.
RT1
Selects RF to be on during retrace.
TR0
Sets 0dB of attenuation when RF is switched off.
TR1
Sets 40dB of attenuation when RF is switched off.
Содержание MG369 C Series
Страница 2: ......
Страница 6: ...Contents 4 PN 10370 10374 Rev F MG369xC GPIB PM ...
Страница 262: ...A 34 PN 10370 10374 Rev F MG369xC GPIB PM ...
Страница 264: ...Index 2 PN 10370 10374 Rev F MG369xC GPIB PM ...
Страница 265: ......