Anritsu MA24 A Series Скачать руководство пользователя страница 1

Operation Manual

Power Sensors
MA24xxA/B/D and 
MA2400xA

Anritsu Company
490 Jarvis Drive
Morgan Hill, CA 95037-2809
USA

Part Number: 10585-00004

Revision: T

Published: April 2011

Copyright 2011 Anritsu Company

Содержание MA24 A Series

Страница 1: ...ration Manual Power Sensors MA24xxA B D and MA2400xA Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA Part Number 10585 00004 Revision T Published April 2011 Copyright 2011 Anritsu Compa...

Страница 2: ...GES TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW IN NO EVENT SHALL ANRITSU COMPANY OR ITS SUPPLIERS BE LIABLE FOR ANY SPECIAL INCIDENTAL INDIRECT OR CONSEQUENTIAL DAMAGES WHATSOEVER INCLUDING WIT...

Страница 3: ...MA2468B MA2468D MA2481A MA2481B MA2481D MA2469B MA2469C MA2469D MA2472A MA2472B MA2472D MA2482A MA2482D MA2442A MA2442B MA2442D MA2490A MA2491A MA2423A MA2423B MA2423D MA2473A MA2473D MA2424A MA2424B...

Страница 4: ...s need to be broken or shredded to such a degree that they cannot be unlawfully used for military purposes CE Conformity Marking Anritsu affixes the CE Conformity marking onto its conforming products...

Страница 5: ...MA24xxA B D MA2400xA OM PN 10585 00004 Rev T FM 5 European Parliament and Council Directive 2002 96 EC Chinese RoHS Compliance Statement...

Страница 6: ...FM 6 PN 10585 00004 Rev T MA24xxA B D MA2400xA OM...

Страница 7: ...the equipment Symbols Used in Manuals Danger This indicates a very dangerous procedure that could result in serious injury or death or loss related to equipment malfunction if not performed properly...

Страница 8: ...ive symbols may or may not be used on all Anritsu equipment In addition there may be other labels attached to products that are not shown in the diagrams in this manual This indicates a prohibited ope...

Страница 9: ...in grounded power outlet If a grounded 3 pin outlet is not available use a conversion adapter and ground the green wire or connect the frame ground on the rear panel of the equipment to ground If powe...

Страница 10: ...the instrument and test devices by wearing a static discharge wristband Alternatively you can ground yourself to discharge any static charge by touching the outer chassis of the grounded instrument b...

Страница 11: ...enus and Soft Buttons 1 3 User Interface Navigation Conventions 1 3 1 4 Identification Numbers 1 4 1 5 Online Manual 1 4 1 6 Test Equipment List 1 4 1 7 Sensor Handling Requirements 1 5 1 8 Sensor Rep...

Страница 12: ...1 Introduction 3 1 3 2 Power Sensor Precautions 3 2 3 3 RF Connector Precautions 3 3 3 4 Connection Techniques 3 4 Connection Procedure 3 4 Disconnection Procedure 3 5 3 5 RF Connector Care 3 5 Visua...

Страница 13: ...Examples 4 9 4 6 Cal Factor Uncertainty 4 11 Calibration Factor Uncertainty Tables 4 11 Appendix A Test Records A 1 Introduction A 1 A 2 Measurement Uncertainty A 1 A 3 Test Records A 1 A 4 SWR Perfo...

Страница 14: ...ued B 2 Performance Specifications B 1 Standard Diode Power Sensors B 2 Thermal Sensors B 4 High Accuracy Sensors B 6 Universal Power Sensors B 8 Pulse Power Sensor B 9 Wide Bandwidth Power Sensors B...

Страница 15: ...racy speed and flexibility in a low cost package With various families of Power Sensors to choose from you can trust you ll find the right combination for precision power measurement Anritsu Power Sen...

Страница 16: ...D 10 MHz to 40 GHz 70 dBm to 20 dBm MA2475D 10 MHz to 50 GHz 70 dBm to 20 dBm High Accuracy Diode Sensors MA2442D 10 MHz to 18 GHz 67 dBm to 20 dBm MA2444D 10 MHz to 40 GHz 67 dBm to 20 dBm MA2445D 10...

Страница 17: ...h as Press the front panel Frequency key User Interface Menus and Soft Buttons The power meter user interface consists of menus button lists sub menus toolbars and dialog boxes All of these elements a...

Страница 18: ...substitute test equipment having the same critical specifications as the test equipment indicated in the test equipment list refer to Measurement Uncertainty on page 4 8 and Cal Factor Uncertainty on...

Страница 19: ...e are no user serviceable parts inside the power sensors Contact your local Anritsu Service Center and return the power sensor with a detailed description of the observed problem Various coaxial adapt...

Страница 20: ...instruments 1 10 Service Policy The power sensor service policy is to exchange the complete unit This policy ensures minimum down time for the customer Unit Exchange Policy The customer returns the p...

Страница 21: ...nsing element Therefore they have only one voltage versus power relationship Universal sensors have three power sensing elements and they have three sets of voltage versus power relationships Power Se...

Страница 22: ...itsu MA247xD standard diode sensors are designed for use with the ML2430 ML2480 and ML2490 series power meters They are designed for high dynamic range high accuracy CW and TDMA measurements These pow...

Страница 23: ...to 20 dBm Accurate CW average power measurements Wide frequency coverage from 10 MHz to 50 GHz sensor dependent Calibration factors stored in EEPROM MA248xD Universal Sensors Description The MA248xD...

Страница 24: ...ical data of wideband signals Features Ideal for measuring radar and communication signals like WiMAX WCDMA WLAN GSM and others CW and Average power measurements as low as 60 dBm 20 MHz video bandwidt...

Страница 25: ...or and linearity correction data This results in assured accuracy when measuring any signal Features True RMS detection enables accurate average power measurements of any signal type 50 dB dynamic ran...

Страница 26: ...both open and closed loop power control testing Pulses down to 1 s can also be captured and displayed thanks to the sensor rise time of 0 6 s In profile mode the meter can be used to measure average...

Страница 27: ...n the field When an RF component connector is mated with a connector having a destructive pin depth damage will usually occur to the RF component connector A destructive pin depth is one that is too l...

Страница 28: ...do not drop or otherwise treat them roughly Mechanical shock will significantly reduce their service life Avoid Applying Excessive Power Exceeding the specified maximum input power level will permanen...

Страница 29: ...ry quality devices and like other such devices they require careful handling Keep Connectors Clean Avoid touching connector mating planes with bare hands Natural skin oils and microscopic dirt particl...

Страница 30: ...e Anritsu Company torque wrench and open end wrench part numbers for different connectors 1 Hold torque wrench at the end 2 Rotate only the connector nut when you tighten the connector Use an open end...

Страница 31: ...are assembled into a system and forgotten but some especially on test equipment are used almost continuously The care and cleaning of these connectors is critical to accurate and reliable performance...

Страница 32: ...blisters The connectors may lose some gloss over time due to usage Light scratches marks and other cosmetic imperfections can be found on the mating plane surfaces These should be of no cause for conc...

Страница 33: ...l connectors will detect and prevent the following problems Positive Pin Depth Positive pin depth can result in buckling of the fingers of the female center conductor or damage to the internal structu...

Страница 34: ...w in Figure 3 2 to accurately measure pin depths Based on RF components returned for repair destructive pin depth of mating connectors is the major cause of failure in the field When an RF component i...

Страница 35: ...to ensure suitability and to avoid connector damage When gauging pin depth if the test device connector measures out of tolerance see Table 3 2 in the region of the gauge see Figure 3 2 on page 3 9 t...

Страница 36: ...ors Table 3 2 Pin Depth Tolerances and Gauge Settings Connector Type Pin Depth Inches Anritsu Gauge Setting GPC 7 0 000 0 003 Same as pin depth N Male 0 003 0 207 0 000 0 000 0 207 0 003 N Female 0 00...

Страница 37: ...llowing are some important tips on cleaning connectors Use only isopropyl alcohol as a solvent Use only lint free cotton swabs Always use an appropriate size of cotton swab Gently move the cotton swab...

Страница 38: ...cotton swab is not too large Use only enough solvent to clean the surface Use the least possible pressure to avoid damaging connector surfaces Do not spray solvents directly on to connector surfaces 4...

Страница 39: ...Dampen only DO NOT saturate Use only isopropyl alcohol and the proper size of cotton swab Gently rotate the swab around the center pin being careful not to stress or bend the pin or you will damage th...

Страница 40: ...3 14 PN 10585 00004 Rev T MA24xxA B D MA2400xA OM 3 6 Connector Cleaning Chapter 3 Power Sensor Care...

Страница 41: ...output voltage The Anritsu ML2400 Series power meters interpret the sensor voltages with signal frequencies and output correct power readings Power Sensing Elements Both diode sensors and thermal sen...

Страница 42: ...match Any suspect power sensor should have two parameters tested SWR magnitude of reflection coefficient Sensitivity 4 3 SWR Performance Power sensor SWR performance in terms of reflection coefficien...

Страница 43: ...rn loss in dB The return loss to magnitude of reflection coefficient conversion equations are 3 Record the measured data in the applicable test records in Section A 4 of Appendix A If the measured ref...

Страница 44: ...itsu 41KC 20 Fixed Attenuator or equivalent with attenuation accuracy of better than 0 5 dB at 2 GHz required for testing the Universal power sensor Various adapters as needed Setup ML24xx Power Meter...

Страница 45: ...ut dBV 10 log V where V is the sensor output voltage Procedure Standard Power Sensors This procedure applies to the following power sensors MA2400xD Thermal Sensors MA247xD Series Standard Diode Power...

Страница 46: ...he signal source 5 Set the range hold on the power meter by pressing the following keys in sequence Sensor Setup More 6 Press the Hold soft key until the display reads Range Hold 2 7 Read and record t...

Страница 47: ...ay be defective Table 4 1 Sensitivity Performance Test Sensor Sensor Input Power dBm Actual dBV Measured Sensitivity dBV MA2411A B 20 3 6 to 4 3 MA244xx 0 7 7 to 6 1 MA246xx 0 7 7 to 5 9 MA247xx 0 5 7...

Страница 48: ...power measurement mode Press the following hard or soft keys in the sequence shown 1 Press the Preset menu key 2 Press the down arrow on the keypad until Factory is highlighted 3 Press the Select sof...

Страница 49: ...ion Factor Uncertainty Sensor Calibration Factor Uncertainty is defined as the accuracy of the sensor calibration at a standard calibration condition Anritsu follows the industry standard condition of...

Страница 50: ...MA2442D MA2472D Instrumentation Accuracy Rectangular 0 50 0 50 0 50 Sensor Linearity Rectangular 1 80 1 80 1 80 Noise 256 Average Normal at 2 0 01 0 01 0 00 Zero Set and Drift Rectangular 0 06 0 04 0...

Страница 51: ...t Refer to Section 1 11 for contact details Calibration Factor Uncertainty Tables The values in Table 4 3 starting on page 4 12 are the uncertainty of the cal factor information stored in the EEPROM f...

Страница 52: ...0 55 0 84 0 84 1 36 1 37 1 36 1 37 1 37 2 27 0 92 0 94 0 94 0 30 0 78 0 57 0 57 0 56 0 83 0 83 1 40 1 42 1 40 1 42 1 41 2 25 1 01 1 03 1 02 0 50 0 66 0 56 0 56 0 55 0 77 0 77 0 96 0 96 0 96 0 96 0 96...

Страница 53: ...8 2 28 3 53 2 43 2 43 2 43 19 00 N A N A N A N A N A N A 2 86 2 84 2 86 2 84 2 84 4 18 2 65 2 65 2 65 20 00 N A N A N A N A N A N A 2 51 2 48 2 51 2 48 2 47 3 15 2 86 2 86 2 86 21 00 N A N A N A N A N...

Страница 54: ...2 94 2 97 2 96 35 00 N A N A N A N A N A N A N A N A 3 19 3 22 3 21 4 95 2 65 2 67 2 66 36 00 N A N A N A N A N A N A N A N A 2 96 3 00 2 99 4 38 3 61 3 63 3 62 37 00 N A N A N A N A N A N A N A N A 2...

Страница 55: ...N A N A N A N A N A N A N A N A N A N A 9 03 9 92 9 41 49 00 N A N A N A N A N A N A N A N A N A N A N A N A 9 29 10 15 9 65 50 00 N A N A N A N A N A N A N A N A N A N A N A N A 10 16 10 95 10 49 a...

Страница 56: ...ance Verification Table 4 4 MA2400xA Sensor Cal Factor Uncertainty Frequency MA24002A MA24004A MA24005A GHz 10 MHz to 50 MHz 2 00 3 00 3 00 50 MHz to 6 GHz 1 00 2 50 2 50 6 GHz to 18 GHz 1 60 4 60 3 7...

Страница 57: ...edure The statement s of compliance with specification2 is based on a 95 coverage probability for the expanded uncertainty of the measurement results on which the decision of compliance is based For s...

Страница 58: ...lection coefficient magnitude MA247xA Frequency 37000 System Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncerta...

Страница 59: ...ons MA2472B D Frequency 37000 System Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncertainty is from 54000 Scala...

Страница 60: ...flection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncertainty is from 54000 Scalar Measurement System 0 310 50 MHz 150 M...

Страница 61: ...ystem Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncertainty is from 54000 Scalar Measurement System 0 310 50 M...

Страница 62: ...ons MA2442B D Frequency 37000 System Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncertainty is from 54000 Scala...

Страница 63: ...erial Number Options MA2481A Frequency 37000 System Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncertainty is f...

Страница 64: ...A2481B D MA2482A D Frequency 37000 System Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncertainty is from 54000...

Страница 65: ...mance Data Model Date Operator Serial Number Options MA249xA Frequency 37000 System Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 50 MHz 150 MHz 0 012 0 07...

Страница 66: ...ta Appendix A Test Records Model Date Operator Serial Number Options MA2411x Frequency 37000 System Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 300 MHz 2...

Страница 67: ...em Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncertainty is from 54000 Scalar Measurement System 0 048 50 MHz...

Страница 68: ...MA2469A MA2469B obsolete Frequency 37000 System Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncertainty is from...

Страница 69: ...8B D MA2469C D obsolete Frequency 37000 System Reflection Coefficient Uncertainty Measured Reflection Coefficient Magnitude Specification 10 MHz 50 MHz 0 010 a a 10 MHz to 50 MHz uncertainty is from 5...

Страница 70: ...r Serial Number Options A 5 Sensitivity Performance Data Sensor Sensitivity Performance Sensor Sensor Input Power dBm Actual dBV Measured Sensitivity dBV MA2411A B 20 3 6 to 4 3 MA244xx 0 7 7 to 6 1 M...

Страница 71: ...N 11410 00423 for the power sensors listed can be downloaded from the Anritsu Internet site http www anritsu com The data sheet provides the most recent performance specifications for the various mode...

Страница 72: ...20 dBm SWR 1 17 10 MHz to 50 MHz MA2472B D only 1 90 10 MHz to 50 MHz 1 17 50 MHz to 150 MHz 1 12 150 MHz to 2 GHz 1 22 2 GHz to 12 4 GHz 1 25 12 4 GHz to 18 GHz 1 35 18 GHz to 32 GHz 1 50 32 GHz to 4...

Страница 73: ...is defined as the time interval necessary for the power sensor to rise from 10 to 90 of the reading when the signal rises instantaneously from zero no power to 1 mW 0 dBm at room temperature b Each p...

Страница 74: ...Bm to 20 dBm SWR 1 90 10 MHz to 50 MHz 1 17 50 MHz to 150 MHz 1 10 150 MHz to 2 GHz 1 15 2 GHz to 12 4 GHz 1 20 12 4 GHz to 18 GHz 1 25 18 GHz to 32 GHz 1 30 32 GHz to 40 GHz 1 40 40 GHz to 50 GHz Ris...

Страница 75: ...as the time interval necessary for the power sensor to rise from 10 to 90 of the reading when the signal rises instantaneously from zero no power to 1 mW 0 dBm at room temperature b Each power sensor...

Страница 76: ...MA2442B D only 1 90 10 MHz to 50 MHz 1 17 50 MHz to 150 MHz 1 08 150 MHz to 2 GHz 1 16 2 GHz to 12 4 GHz 1 21 12 4 GHz to 18 GHz 1 29 18 GHz to 32 GHz 1 44 32 GHz to 40 GHz 1 50 40 GHz to 50 GHz Rise...

Страница 77: ...ssary for the power sensor when used with ML2480A B series power meter to rise from 10 to 90 of the reading when the signal rises instantaneously from zero no power to 10 dBm at 25 C b Each power sens...

Страница 78: ...dBm SWR 1 90 10 MHz to 50 MHz MA2481A only 1 17 10 MHz to 150 MHz 1 12 150 MHz to 2 GHz 1 22 2 GHz to 12 4 GHz 1 25 12 4 GHz to 18 GHz Sensor Linearity 3 10 MHz to 6 GHz 3 5 6 GHz to 18 GHz 1 8 CW wit...

Страница 79: ...1 35 2 5 GHz to 26 GHz 1 5 26 GHz to 40 GHz Rise Time b b Rise Time is defined as the time interval necessary for the power sensor when used with ML2490A series power meter to rise from 10 to 90 of th...

Страница 80: ...z to 18 GHz Rise Time a a ML2480 Series Power Meter Rise Time is defined as the time interval necessary for the power sensor to rise from 10 to 90 of the reading when the signal rises instantaneously...

Страница 81: ...to 40 GHz MA2425A BD 10 MHz to 50 GHz Dynamic Range 30 dBm to 20 dBm SWR 1 90 10 MHz to 50 MHz MA2421A D 1 10 1 17 50 MHz to 150 MHz MA2421A D 1 10 1 10 150 MHz to 2 GHz 1 15 2 GHz to 12 4 GHz 1 20 12...

Страница 82: ...ture Accuracy c 1 0 a Rise Time is defined as the time interval necessary for the power sensor to rise from 10 to 90 of the reading when the signal rises instantaneously from zero no power to 1 mW 0 d...

Страница 83: ...4 GHz 1 25 12 4 GHz to 18 GHz Rise Time a a Rise Time is defined as the time interval necessary for the power sensor to rise from 10 to 90 of the reading when the signal rises instantaneously from ze...

Страница 84: ...B 14 PN 10585 00004 Rev T MA24xxA B D MA2400xA OM B 2 Performance Specifications Appendix B Specifications...

Страница 85: ...ror contributions A 1 ESD 1 6 exchange policy 1 6 F firmware 1 1 G gauge pin depth 3 8 H hard keys navigation 1 3 I inspection 3 5 IPA 3 3 3 10 isopropyl alcohol 3 10 M measurement uncertainty 4 8 mis...

Страница 86: ...versal 2 3 wideband 2 4 service 1 6 soft keys navigation 1 3 specifications B 1 SWR reflection coefficient 4 2 T teflon tuning washers 3 3 test data A 1 sensitivity 4 4 test equipment 1 4 tolerance co...

Страница 87: ......

Страница 88: ...Anritsu Company 490 Jarvis Drive Morgan Hill CA 95037 2809 USA http www anritsu com Anritsu prints on recycled paper with vegetable soybean oil ink...

Отзывы: