ISO 9001:2000 certified. ICMA5KUTASTM64-SPEC05-0806-A4. ©2008 Anritsu. All Rights Reserved.
Page 9 of 14
Error Addition
SONET/DSn
•
A1/A2, B1, B2, REI-L, B3, REI-P, V5, REI-V, FAW (FAS), SFAW, FPS, MAW, Parity P,
Parity CP, F-bit, M-bit, FEBE, CRC-6, PRBS, Word, transmission errors
SDH/PDH
•
A1/A2, B1, B2, MS-REI, B3, LP-B3, HP-REI, V5, LP-REI, FAW (FAS), CRC-4, REI (E-bit or
REBE), PRBS, Word, transmission errors
Error Control
•
Programmable number or rate
SONET/SDH Overhead Editors
SONET
TOH Editor
•
All bytes of TOH (STS-1/STS-3) are programmable except B1/B2, H1/H2/H3 and Z0
•
J0 (Trace Identifier):
o
programmable 62 bytes ASCII sequence, CRLF added or
o
programmable 15 bytes ASCII sequence, CRC (E.164) added or
o
programmable byte
POH Editor (STS)
•
C2, G1, F2, H4, Z3, Z4, N1
•
J1 (Trace Identifier):
o
programmable 62 bytes ASCII sequence, CRLF added or
o
programmable 15 bytes ASCII sequence, CRC (E.164) added or
o
programmable byte
POH Editor (VT)
•
V5, Z6, Z7
•
J2 (Trace Identifier):
o
programmable 62 bytes ASCII sequence, CRLF added or
o
programmable 15 bytes ASCII sequence, CRC (E.164) added or
o
programmable byte
SDH
SOH Editor
•
All bytes of SOH (STM-1) are programmable except B1/B2 and H3
•
J0 (Trace Identifier):
o
programmable 15 bytes ASCII sequence, CRC (E.164) added or
o
programmable 62 bytes ASCII sequence, CRLF added or
o
programmable byte
POH Editor (VC-4 and VC-3)
•
C2, G1, F2, H4, F3, K3, N1
•
J1 (Trace Identifier):
o
programmable 15 bytes ASCII sequence, CRC (E.164) added or
o
programmable 62 bytes ASCII sequence, CRLF added or
o
programmable byte
POH Editor (VC-12)
•
V5, N2, K4
•
J2 (Trace Identifier):
o
programmable 15 bytes ASCII sequence, CRC (E.164) added or
o
programmable 62 bytes ASCII sequence, CRLF added or
o
programmable byte