If the connection is OK, click on the Start Uploading button to start uploading. It will take several minutes 
 to perform software update. If the option "Incremental Update" is not checked, all processors will be  

 

updated (including processors with the same software version).  

 

If you wish to update only the latest versions of processors, check the Incremental Update box. 

 

Avoid interrupting the process. Update status is being displayed in the Info Box window. 

 

When the update is finished, the line with the text “The fixture is successfully updated‘will appear in 

 

 this window and the fixture will reset with the new software. 

 

7. RDM 

This fixture is ready for RDM operation.RDM (Remote Device Management) is a bi-directional communications 
protocol for use in DMX512 control systems, it is the new open standard for DMX512 device configuration and 
status monitoring. 
The RDM protocol allows data packets to be inserted into a DMX512 data stream without adversely affecting 
existing non-RDM equipment. By using a special „Start Code,“ and by complying with the timing specifications for 
DMX512, the RDM protocol allows a console or dedicated RDM controller to send commands to and receive 
messages from specific moving lights. 
RDM allows explicit commands to be sent to a device and responses to be received from it.  
The list of commands for ArcPad 48 Integralis the following. 
 

 

 

 

 

Parameter ID 

Discovery command 

SET command 

GET command 

DISC_UNIQUE_BRANCH 

 

 

DISC_MUTE 

 

 

DISC_UN_MUTE 

 

 

DEVICE_INFO 

 

 

SUPPORTED_PARAMETERS 

 

 

SOFTWARE_VERSION_LABEL 

 

 

DMX_START_ADDRESS 

 

IDENTIFY_DEVICE 

 

DEVICE_MODEL_DESCRIPTION 

 

 

MANUFACTURER_LABEL 

 

 

DEVICE_LABEL 

 

SENSOR_DEFINITION 

 

 

SENSOR_VALUE 

 

 

DISPLAY_LEVEL 

 

DEVICE_RESET 

 

 

DMX_PERSONALITY 

 

DMX_PERSONALITY_DESCRIPTION 

 

 

Содержание ArcPad 48 Integral (SmartWhite)

Страница 1: ...Version 1 5...

Страница 2: ...5 DMX 512 connection 10 3 6 Master slave connection 10 3 7 Stand alone operation 10 4 ArcPad 48 Integral SmartWhite DMX protocol 11 5 Control menu map 12 6 Fixture menu 14 6 1 Fixture Address 15 6 2 F...

Страница 3: ...y Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part Do not overload wall outlets and extension cords as this can result in fire or electric shock...

Страница 4: ...The fixture becomes very hot during operation Allow the fixture to cool approximately 30 minutes prior to manipulate with it Operate the fixture only after having familiarized with its functions Do n...

Страница 5: ...egral can be arranged in any position orientation The ArcPpad 48 Integral s radiator with LEDs is mounted on an adjustable bracket for tilt adjustment into many positions Two slots 8 5mm wide in the f...

Страница 6: ...ith all national and local electrical and construction codes and regulation The ArcPad 48 Integral is equiped with with a 5 cored power data cable The 3 cores serve for the power supply and next 2 shi...

Страница 7: ...ArcPad 48 Integral SmartWhite 7...

Страница 8: ...le 1 Disconnect the fixture from the mains 2 Put the top edge of the barn doors module into the second groove on the top side of the radiator detail A and the bottom edge into the second groove on the...

Страница 9: ...al Interface or RDM Communicator user manuals to get more information about this products The way how to connect these interfaces to the DMX data link is figured below NOTE never connect the RDM commu...

Страница 10: ...y fixture To set the program to be played see the Stand alone setting menu St AL Stand alone operation can be applied to the single fixture or to multiple fixtures operating synchronously Synchronous...

Страница 11: ...uration 100 0 step proportional step proportional 3 0 31 32 63 64 95 96 127 128 143 144 159 160 191 192 223 224 255 Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Open...

Страница 12: ...l 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 A001 dM Ad 001 512 MA SL d AbL MASt SLA InFo Poti FuLL totL rSEt EcO totL rSEt DM In Stro 0 255 F dim 0 255 tEMP Cur t Hi tE rSEt VErS IC1 PErS...

Страница 13: ...Level 5 Menu Level 6 F dim 0 255 Stor dFSE MAn M PrE C WWhi Wh 01 Wh 03 dimr di 01 di 06 Man C WWhi 0 255 dimr 0 255 F dim 0 255 tESt St AL Auto Off tESt PrG 1 PrG 3 PLAY tESt PrG 1 PrG 3 Edit PrG 1...

Страница 14: ...display with the four control buttons will appear on the screen of the RDM communicator The control buttons have the following functions ESCAPE button leaves menu without saving changes ENTER button...

Страница 15: ...pear Now you can fullly control the fixture using the UP Down Enter Escape and Reset buttons 6 1 Fixture Address Use this menu to set the DMX address of the fixture or set the fixture as a Master Slav...

Страница 16: ...m the choice Po ti Power On Time Use the menu item to read the number of operation hours for each LEDs operating mode FuLL Max light output from the fixture totL the function shows the total number of...

Страница 17: ...to turn the display by 180 tEM U Temperature Unit Use this menu in order to display the fixture temperatures in desired units C or F LoAd Load of LEDs The menu allows to choose 2 different operating...

Страница 18: ...ENTER button 5 Use the UP DOWN buttons to select desired program 6 Press the ENTER button to confirm the choice PLAY Playing program By enter to this menu a complete overview of all programs is offer...

Страница 19: ...tory Users should not change the setting uPd M Updating mode The menu item allows you to update software in the fixture via either serial or USB port of PC The following are required in order to updat...

Страница 20: ...tch this fixture to the update mode 1 Run the RDM Network and select menu item Remote LED Display 2 Use the UP DOWN buttons to find SPEC menu 3 Press the ENTER button 4 Use the UP DOWN buttons to sele...

Страница 21: ...or use in DMX512 control systems it is the new open standard for DMX512 device configuration and status monitoring The RDM protocol allows data packets to be inserted into a DMX512 data stream without...

Страница 22: ...versal Interface user manual for detail description of RDM operation 8 Error and information messages t M Er Temperature measuring error The message informs you that the LED module temperature sensor...

Страница 23: ...s Full mode Eco mode 85 000 96 000 All LED channels Full mode Eco mode 85 000 96 000 L70 70 maintenance of initial lumen output in hours Electronics Control USITT DMX 512 RDM DMX protocol modes 4 2 3...

Страница 24: ...ArcPad 48 Integral SmartWhite 24 Dimensions mm ArcPad 48 Integral Junction box Weight 3 kg...

Страница 25: ...1 x Gasket of cable grommet M20 PF P N 1305 1388 Optional accessories 1 x Barn doors module in silver colour No 10980090 Eggcrate top hat module without lenses No 10980091 Flash cable RS232 DMX No 130...

Страница 26: ...pressure water spray Wash the housing with a soft brush or sponge and a mild non abrasive washing detergent Rinse it There are no serviceable parts inside the device Maintenance and service operation...

Страница 27: ...ArcPad 48 Integral SmartWhite 27...

Отзывы: