ArcLine DVP Integral 

 

3. Installation 

 

3.1 Mounting the fixture   

The ArcLine DVP Integral can be arranged in any orientation on a flat, non-flammable surface by means of the wall 

mount adaptor . 

1. Screw both mounting brackets (2) on a flat surface by means of suitable flat-head screws (3). The hole in the 

mounting bracket (2) has a diameter of 6.2mm. 

2. Place the ArcLine DVP Integral (1) into the mounting brackets (2) and secure the unit  by means of the two 

holders (4) with two screws M5x12 (5) each.  

 

 

 

   

 

 

     

 

Ensure that the structure to which you are attaching 

the unit is secure.

 

 

 

3.2 Connecting to mains 

 

The unit must be installed by a qualified electrician in accordance with all national 

and local electrical and construction codes and regulations. 

 

This device falls under class one and must be grounded! 

 

The ArcLine DVP Integral is equipped with auto-switching power supply that automatically adjusts to any 50-60Hz 

AC power source from 100-277 Volts. 

A 5-cored cable Flamar Li9YC11Y with 12-pin conector Chogori  serves for data/power input. Three cores  serve for 

the power supply  and next  2 shielded cores are intended for  DMX connection as shown in the table.  

Core 

Connection 

Core 

Connection 

Black 

Live 

Red 

Data + 

Blue 

Neutral 

White 

Data - 

Yellow/Green 

        

Shielding 

 

The ArcLine DVP module should be connected to the Data Configurator unit which allows power supply of the 

ArcLine DVP modules and their addressing and setting. Please see the user manual of the Data Configurator.  

Содержание ArcLine DVP 1200 Integral

Страница 1: ...Version 1 3...

Страница 2: ...e exterior view 4 3 Installation 5 3 1 Mounting the fixture 5 3 2 Connecting to mains 5 3 2 Connecting ArcLines DVP Integral with the Data Configurator 7 3 3 Installing diffuser 10 4 Technical specifi...

Страница 3: ...cleaning servicing or installing Do not overload wall outlets and extension cords as this can result in fire or electric shock Make sure the power cord is never crimped or damaged by sharp edges Check...

Страница 4: ...mately 30 minutes prior to servicing or maintenance Operate the fixture only after having familiarized yourself with its functions Do not permit operation by persons not qualified to operate the fixtu...

Страница 5: ...ectrician in accordance with all national and local electrical and construction codes and regulations This device falls under class one and must be grounded The ArcLine DVP Integral is equipped with a...

Страница 6: ...ed according to IP 67 by mating with related Chogori cable panel connectors They cannot stay disconnected outdoor To protect input output connectors against dust during fixtures installation cover the...

Страница 7: ...are used For connection between the Data Configurator and first ArcLine DVP fixture serves the Lead Cable Data Configurator to ArcLine DVP Both LED outputs of the Data Configurator are used If you in...

Страница 8: ...an be connected to the one LED output of the Data Configurator or divided into both LED outputs e g Output A 10 fixtures output B 30 fixtures Maximum distance between the Data configurator and the las...

Страница 9: ...e DVP Integral 9 The following picture shows possible combinations of the ArcLines DVP Integral and a need of Connection cables ArcLine DVP to ArcLine DVP in some cases of their installation in a clos...

Страница 10: ...wer before installing diffuser 1 Remove two side caps 1 on the DVP Integral housing by unscrewing four screws 2 on each side 2 Screw new side caps 3 to the housing 3 Insert the diffuser 4 on the housi...

Страница 11: ...200 Integral 48 x multi chip RGB LED Beam angle 120 without diffuser Projected Lumen maintenance 60 000 hours L70 25 C Control Protocol USITT DMX 512 Pixel control Smooth led intensity control 0 100 C...

Страница 12: ...ArcLine DVP Integral 12 With round diffuser With flat diffuser Wall mount adaptor assembled...

Страница 13: ...x mounting bracket P N 12051159 03 2x mounting holder P N 12051160 01 1 x User manual Optional accessories Diffuser ArcLine DVP 600mm flat P N 19020280 Diffuser ArcLine DVP 900mm flat P N 19020281 Dif...

Страница 14: ...ice operations are only to be carried out by a qualified person Should you need any spare parts please use Anolis OEM parts 5 1 Disposing of the product To preserve the environment please dispose or r...

Отзывы: