Pump Storage 

It is important to comply with the recommendations for storage in the operator's manual of the machine 

into which the pump is incorporated. 
For the pump itself, at the end of pumping operations it is essential to flush out the pump by pumping clean 
water.  After this, open the pump inlet to air and leave the pump in operation until the pump is completely 
empty.  Following this simple procedure at the end of every operating session will prevent the retention 
inside the pump of products which are often corrosive and may damage its wetted parts over the long-
term. 
If the pump is in storage during the winter in locations with severe weather conditions, it is very important to 
flush out the internal circuit as described above and then fill the pump with A

/R

 

P

ump 

S

aver, A

R64511

. Then 

take care to drain the liquid from the system and the pump.

Putting the pump back into service 

Before putting the pump back into service after storage, check the oil level and the tightness of the 

mounting screws. 

Scrapping the pump 

Used units must be disposed of in compliance with local legislation. 

A/R Pump Saver

P/N 64511

Protects Pumps from

Freezing Conditions

Содержание BHS170-C/C

Страница 1: ...HS170 C C 42 4 160 4 725 50 19 3 143 3 BHS200 C C 51 2 193 7 725 50 22 1 143 3 diAPHRAgm KiTS modeL deScRiPTion AR43323 BlueFlex AR43322 Desmopan AR43321 NBR VALVe KiTS modeL deScRiPTion AR2374 Valves...

Страница 2: ...o not draw in liquids at temperatures above 50 C or below 5 C Do not use the pump in drinking water supply systems Do not use the pump on products for human consumption Do not use the pump on pharmace...

Страница 3: ...diagram guideline The following is a simplified illustration of the typical installation layout and is purely a guideline Control Unit by pass Control Unit Delivery line filter Tank Agitation Pump In...

Страница 4: ...see Technical Data free from restrictions and elbows and with a filter of suitable capacity see Installation For occasional duty such as filling water supply tanks the pump can be operated at a vacuum...

Страница 5: ...issing ordamaged contact the dealer or manufacturer to agree the procedures to be followed The packaging material must be disposed of appropriately in accordance with the relevant statutory require me...

Страница 6: ...g a vacuum gauge to the pump intake fitting The rated pressure of the outlet hose fittings and clamps must be no less than the maximum rated pressure ofthe pump Replacing the intake and outlet fitting...

Страница 7: ...evel as described in the Checking the oil level section Before putting the pump into operation check that the control unit is set for low pressure Starting and stopping the pump To start the pump proc...

Страница 8: ...rtridge See Inspecting the filter Pump Checking the oil level See Checking the oil level Connection of pump to power Inspection Every working day source pulley belt coupling Pump Inspect mounting See...

Страница 9: ...placed Inspecting the Inlet Filter Inspect the inlet filter cartridge If the cartridge is fouled wash it thoroughly to remove the dirt If the cartridge is torn or cracked it must be replaced Checking...

Страница 10: ...he pump of products which are often corrosive and may damage its wetted parts over the long term If thepump is instorageduring the winter in locations with severe weather conditions it is very importa...

Страница 11: ...Restriction in intake circuit Intake filter fouled Intakecircuit not airtight Residual air left inside pump Valve plate stuck to its seat Pressure accumulator deflated Pressure accumulator deflated R...

Страница 12: ...t worn Oil pressure inside pump too high Restore correct oil level in tank One or more diaphragms ruptured Stop the pump at once Replace the diaphragms 1 Oil on pump body or base Pumpusing too much oi...

Страница 13: ...ORTH AMERICA 11 12 14 15 16 19 18 19 23 22 20 20 25 25 19 18 21 24 32 20 23 17 26 49 51 50 53 42 29 27 28 30 31 33 34 35 52 40 39 48 46 43 43 40 39 38 37 36 77 78 79 80 45 42 41 81 3 4 2 5 6 7 9 8 1 1...

Страница 14: ...0211 Elbow 1 1 2 1 37 2240200 Ring nut 1 3 4 G 1 38 390210 O ring 39 69x3 53 1 39 680070 O ring 31 5x4 25 8 40 759051 Valve 8 41 130491 Ball valve 3 8 G 1 2 GM MDX 1 T T180 42 110130 Ring nut 1 2 2 43...