Anleaf Technologies AP300W Скачать руководство пользователя страница 6

 

2.1

. High Power Storage Battery   

If the LED indicates green light, the power of battery shows in full level and the voltage is above 12.6V 

usually. 

 

2.2.

 Low Power Storage Battery 

If  the  LED  indicates  yellow  light,  the  battery  power  shows  in  low  level,  then  user  can  choose  the  DC 

output; the battery could be used for some time. 

 

2.3. 

Protection for Low Voltage 

If the red LED light is flashing, the Under-Voltage-Protection (UVP) will be working at once. When the 

UVP is working, the protection system will reject any operation  and auto checks up the status of battery 

storage. At this stage, if the voltage is under 9.6V, the LED display will auto shut off. 

 

3. Discharging: 

The  most output  is 360W including AC/DC discharging at the same time. If the

 master switch is 

turned on, the device will be ready for operation; user should pay attention to the status of battery power. 

 

3.1.

 AC Discharge (300W/600VA)

 

In using AC output, please turn on the AC power switch. User should care about the input ratings of load 

&  also  check  what  the  voltage  is  (110VAC  or  220VAC).  Note:  5VDC  USB  socket  is  set  up  at  this  unit 

with a rating of 5VDC/500m A. 

 

3.2. 

DC Discharge (Constant DC output socket & Car cigarette output socket is 12VDC/6A) 

In using DC output, please turn on the DC power switch. User should care about the input ratings of load 

&  check  if  the  DC  rating  is  less  than  the  power  consumption.  Please  refer  to  the  DC  outlet  rating  as 

specification. 

 

Trouble Shooting: 

1. If AC load cannot keep working, please check up the solar power bank according to the following 

procedures: 

1.1. Please check if the rated power of the load is 

300W ? 

1.2. If  the rate is the same as 

300W condition, please check  whether the voltage of battery storage has 

got a “Duty Cycle”. Usually High Electric Potential will drive the AC load, but if an AC load gets higher 

wattage, it will absorb higher current draw and also work continually, the UVP will be started to protect the 

system and auto shut down. In this case, please check whether DC outlet is working normally, if so, please 

re-charge the battery. 

1.3. If the LED display of battery storage shows the status of full or normal power however the AC output 

cannot work, the UVP will be started due to the single cell volt may be dropped to 2.4V.   

If the single cell gets such problem, it could be aging, we suggest that you should change into new battery 

or send it back for investigation.   

 

Содержание AP300W

Страница 1: ...nleaf Technologies Co Ltd No 68 6 Zhongxiao Street Tuku Township Yunlin County 63359 Taiwan website www anleaf com tw e mail jh anleaf msa hinet net USER GUIDE Portable Solar Power Generator Model AP300W ...

Страница 2: ...O P sockets Pure Sine Wave 3 PV I P 2 terminal block for 25AMax total 11 USB DC O P socket 5VDC 4 AC I P LED 100V 240Vac 50 60Hz 12 Battery Storage Display Switch 5 Charge status LED Charge status of system 13 Battery Storage LED Display 6 DC O P Switch LED 14 Carrying handle 7 Car cigarette O P socket 12VDC of battery 15 Trolley and Brake 8 DC O P socket 24V 70W ...

Страница 3: ...6 DC AC inverter and 5VDC DC USB port 2 7 DC DC converter 2 8 The LED display of battery storage shows the voltage as power energy of battery Specifications Item Condition Value Unit Input Solar Panel Input Power Terminal block total 80Wp default option Vmp 23V Imp 25A 20 360 Wp DC plug each 80Wp default option Imp 8A Vmp 24V 20 120 Wp AC power socket AC100 240V 50 60Hz 100 240 Vac Ratings for sol...

Страница 4: ...cuit low voltage overheating reverse connection inrush voltage and over load 3 Hybrid input power source AC Source and Solar Power Source 4 Working as power supply system DC AC UPS or a secondary battery 5 Equipped with battery LiFePO4 and built in protection system 6 The device can meanwhile be working on charging and discharging mode 7 Auto detects the storage of battery if the power energy of b...

Страница 5: ...nnects up the terminal block of Solar Power Box and also check if everything is right for the red cable terminal to the positive and the black or blue cable terminal to the negative of the terminal blocks on the solar power box 1 2 3 In using the DC plug user should connect the male DC cable of PV panel with the female DC socket 1 2 4 If the power energy of battery is on charge completion the LED ...

Страница 6: ... with a rating of 5VDC 500m A 3 2 DC Discharge Constant DC output socket Car cigarette output socket is 12VDC 6A In using DC output please turn on the DC power switch User should care about the input ratings of load check if the DC rating is less than the power consumption Please refer to the DC outlet rating as specification Trouble Shooting 1 If AC load cannot keep working please check up the so...

Страница 7: ...e battery up to full power 4 Both voltage rating and device do not match up If the device cannot work or be burnt the problem is that both nominal voltages cannot match up Please recheck the specification of power supply unit and solar power bank 5 Reduction of working wattage hour under different discharge current In the same condition for batteries the voltage maybe offer different power energy ...