background image

Remove plug from socket when not in use.

During sterilising, if the lid is opened, the program will end automatically to protect human body from 
direct radiation. 
Closing the lid will not restart the program. User shall follow operation procedures on pages 5 and 6 
to restart the program.

Usage Method

Preparation for Operation 

Functions & Operation

1.  Wash and dry the bottles you wish to sterilise before placing into the UV steriliser.
2. Hang the accessories basket on the liner hook, then put the teats that needs to be dried and    

sterilised into the accessories basket.

3. Close the display cover.

”DRY” function : 
This function is used only when drying items, no sterilise function will be performed.
(1) Before using the DRY function, open the display cover as shown in Figures 1 and 2.
(2) Place the bottles/teats to be dried into the inner tank/accessories basket and close the display 

cover as shown in Figures 3 and 4.

(3) Plug the steriliser into the mains socket.
(4) Press the "Dry" button. The time display light will flash for 3 seconds. The LED light will be on. The 

remaining time will be displayed. The air exchange will take place in the last 60 seconds of the 
cycle. There are 2 drying options : 41/51 minutes. Press the "Dry" function button again to cancel if 
required.

1.

Sterilise Function:
This function is used to sterilise items only, no drying function will be performed.
(1) Before using the "Sterilise" function, open the display cover as shown in Figures 1 and 2.
(2) Place the bottles/teats to be sterilised into the inner tank/accessories basket and close the 

display cover as shown in Figures 3 and 4.

(3) Plug the steriliser into the mains socket.
(4) Press the "Sterilise" button. The time display will flash 3 times, then the program will start. Digital 

 display shows remaining operation time.

There are 3 operation times for selection. The default time is 11 minutes. Press again for 16 
minutes and press twice for 21 minutes. Press one more time to turn off the appliance.

2.

“Auto” Function:
This function is used to both sterilise and dry.
(1) Before using the “Auto” function, open the display cover as shown in the Figures 1 and 2.
(2) Place the bottles/teats to be dried and sterilised into the inner tank/accessories basket and 

close the display cover as shown in Figures 3 and 4.

(3) Plug the steriliser into the mains socket.
(4) 

3.

“Storage” Function:
This function is to be used to store the clean items.
(1) Before using the “Storage” function, open the display cover as shown in Figures 1 and 2.
(2) Put the bottles/teats to be dried and sterilised into the inner tank/accessories basket and close 

the display cover as shown in Figures 3 and 4.

(3) Plug the steriliser into the mains socket.
(4) Press the "Storage" button. The time display will flash 3 times, then the program will start.
(5) This is a 2 stage program. It begins with 51 minutes "Auto" function, then followed by 72 hours

"Storage" function.

(6) During "Storage" period, the unit will perform the sterilisation process every 2 hours.
(7) Press "Storage" button again to turn off the appliance.

4.

5.

Note: When the “DRY” function is completed, the buzzer sounds 6 times. It enters the standby mode.

Note: When the “Auto” function is completed, the buzzer sounds 6 times. It enters the standby mode.

Note: When the "Storage” function is completed, the buzzer sounds 6 times. It enters the standby mode.

Note: 

Note: When the "Sterilise" function is completed, the buzzer sounds 6 times. It enters the standby mode.

Press the "Auto" button. The time display will flash 3 times, then the program will start. 
Drying function will be carried out first, followed by the sterilisation. The air exchange will 
take place in the last 60 seconds of the operation cycle. There are 2 operation durations for 
selection. The default time is 51 minutes. Press again for 61 minutes. Press one more time to 
turn off the appliance.

Содержание 42963080

Страница 1: ...IN CHINA FOR AU NZ IMPORTED FOR KMART STORES IN AUSTRALIA AND NEW ZEALAND KEYCODE 42 963 080 3 In 1 Steriliser Instruction Manual IMPORTANT READ CAREFULLY BEFORE USE AND RETAIN FOR FUTURE REFERENCE Sterilise ...

Страница 2: ...or feature without further notice Catalogue User Manual Warning Caution Product Introduction Specification Panel Features Parts of product Introduction of UV Steriliser Tips for Use Usage Method Preparation for Operation Functions Operation Cleaning Maintenance Caution Cleaning Method Note Warranty 1 1 2 2 2 4 3 4 5 6 5 6 5 6 7 7 7 7 8 ...

Страница 3: ...or parts produced by other manufacturers 2 Keep the product out of reach of children 3 Check if the voltage indicated on the bottom of the appliance corresponds to local mains voltage 0 before you connect the appliance 4 Dispose of all packaging materials to avoid suffocation risks 5 The appliance is designed for indoor use only 6 If there is any breakage or damage to the appliance please do not u...

Страница 4: ...th filter Bottle teats and Accessories Sterilisation Area Baby Bottle Sterilisation Area Caution The height of the baby bottles should not exceed 16cm Parts of Product A Display Cover B Reflex housing C Accessories basket D Base cover E UV lamp F Sealing ring G Inner Tank H Base Introduction of UV Steriliser Tips for Use Before placing each bottle try to dry the water inside the bottles Press the ...

Страница 5: ...ration times for selection The default time is 11 minutes Press again for 16 minutes and press twice for 21 minutes Press one more time to turn off the appliance 2 Auto Function This function is used to both sterilise and dry 1 Before using the Auto function open the display cover as shown in the Figures 1 and 2 2 Place the bottles teats to be dried and sterilised into the inner tank accessories b...

Страница 6: ...duct can be addressed to our Customer Service Centre at 690 Springvale Rd Mulgrave Vic 3170 Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be o...

Отзывы: