Service menu continued ….
Main item
Sub item
Sub
Item
Range
Description
2.3 Recipe setting
(continued…)
<Recipe name> 1
<Recipe name> 10
DV 4 WT
0,0-30,0 s
Waiting time Water 4
DV 4
0-100 ml
Dispensing amount Water 4
(Hot water dispensed)
DV 5 WT
0,0-30,0 s
Waiting time Water 5
DV 5
0-100 ml
Dispensing amount Water 5
(Hot water HS DUO)
DV 6 WT
0,0-30,0 s
Waiting time Water 6
DV 6
0-100 ml
Dispensing amount from an extra inlet
valve Water 6 (Cold Water option)
Service menu continued…
Main item
Sub item
Item
Range
Set-
ting
Description
2.4 Settings
Language
English
Language choice display.
Ex factory setting English.
Dutch
German
French
Temperature
Temp. boiler
70-95°C *
85°C *
Boiler temperature standard model
AA - 4A
OV Choco till OV4
90°C *
Boiler temperature Fre
instant model 5A t/m CA
OV 1 TS till OV HS DUO
Hysteresis
2-10°C
2°C
Temperature drop, after which boiler
must reheat
Output block
70-80°C
78°C
Boiler temperature disables dispens-
ing. Display: [Out of order, boiler
heating]
Output release
70-82°C
83°C
Boiler temperature allows dispens-
ing again
Stand-by
60-95°C
60°C
Boiler temperature during stand-by
Extended Heating
0-5 sec
0 sec
To maintain the optimum boiler tem-
perature the heating element and
inlet valve switch on simultaneously.
Set the waste delay of the element
here after the inlet valve is closed.
Inlet valve
Heating
Display
Show clock
Yes/no
No
Show clock in display
Show date
Yes/no
No
Show date in display
Message text
Yes/no
No
Show message text (running text) in
display. Only shown if Display Date,
Clock or both are set to no.
Message text only programmable
by using the Optimizer programme
and SD card.
Use bleeper
Yes/no
Yes
Sound signal on or off
Ventilator
Fan time
0-300 sec.
60 s.
Duration of Fan speed 2 after
dispensing
Fan speed 1
40-100%
50%
Fan speed when resting
Fan speed 2
70-100%
100%
Fan speed during dispensing
Inlet valve
Heating