![Anilam RBS-T Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/anilam/rbs-t/rbs-t_installation-manual-and-owners-manual_2943810018.webp)
RBS-T Linear Encoder Installation Manual and Owner’s Guide
P/N 70000426
All rights reserved. Subject to change without notice.
Page 15 of 43
03-Nov-98
7. Using a torque wrench, tighten the two mounting screws to 24 in-lbs. Tightening the
reader head mounting screws should pull the reader head back against the jack
screws taking out the 0.004” and restoring its original position.
If the reader head does not return to within 0.001” of its original position, loosen the
mounting screws and repeat the alignment procedure. When repeating the
procedure, compensate the adjustments so the reader head returns to its original
position when the mounting screws are tightened.
8. Remove the plastic alignment brackets from the reader head.
NOTE:
Save the plastic alignment brackets. If the encoder is ever removed from
the machine, it cannot be reinstalled without the reader head alignment brackets.
9. After the installation is complete, perform a second visual inspection of the reader
head. Reinstall both end caps.
X Axis Installation (Back Side of Table) Lagun and Bridgeport Machines
No brackets are required to perform an X-axis installation on the back side of the table for
either a Bridgeport or Lagun type machine.
Installing and Aligning X Axis Encoder
In this installation, the encoder is mounted to the machined surface on the back side of
the table. The reader head extends below the table and is mounted directly to the
saddle. When the encoder is placed against the back surface of the table, the saddle
should not interfere with the reader head’s alignment (when the plastic reader head
alignment brackets are installed).
1. Before installing the encoder, remove both end caps and visually check the
alignment of the reader head. Verify that the reader head is centered within the
housing and is not twisted in any way. Do not reinstall the end caps at this time.
2. Refer to
Figure 12, X Axis Encoder Positioning
. Center the X axis encoder along the
length of the rear face of the table, with the bottom of the encoder even with the
table’s bottom. Two bar magnets placed against the lower face of the table way
make a good temporary support.