Anhui Yine YN-CA Buck Series Скачать руководство пользователя страница 3

YN-C Buck series solar charge controller

1

I. Safety instructions:

1.1 Safety signs

The following safety symbols may appear in this manual and their meanings are as

follows:

safety symbols

signification

Danger

Indicates that if the safety warning is ignored, there is a serious

accident that may lead to personal injury.

Warning

Indicates that if safety warnings are ignored, there is a risk of serious

injury, serious equipment damage or major business interruption.

Notice

This means that if safety warnings are ignored, there is a risk of

moderate injury, moderate equipment damage or partial business

interruption.

Insturction

Indicates that the content is additional information for the body.

For electrical and electronic equipment, safety involves the entire process of installation,

commissioning, operation and maintenance. Therefore, incorrect use or misuse will

endanger the life and personal safety of the operator or a third party and the safety of the

equipment. In order to avoid personal injury and damage to the equipment, all safety,

warnings and cautions such as the following are strictly observed during operation and

maintenance.

1.2 Safety instructions

Warning

All installation operations on the controller must be performed by a qualified technician.

Professional and technical personnel must undergo special training, complete the manual and

understand the safety related to the operation.

If a non-professional person performs installation operations and causes personal injury,

the company will not be responsible.

Failure to install and operate the controller in accordance with the instructions in this

manual will result in damage to the controller and will not be covered by our warranty.

Before installion

Notice

When receiving the product, first check the MPPT series controller for damage during

transportation. If you find any problem, please contact our company or the transportation

company immediately.

installing

Before installing the MPPT controller, make sure that the MPPT controller has not been

electrically connected and powered.

Содержание YN-CA Buck Series

Страница 1: ...uck Series Solar Charge Controller User Manual Anhui Yine Technology Co Ltd Dear customer thank you for choosing our products Please read the following instructions carefully before using this product...

Страница 2: ...ion instructions 6 3 Wire 7 4 photovoltaic array requirements 9 5 able selection requirements 9 6 Communication port description 9 IV Operate instruction 10 4 1 Indicator function 10 4 2 Setting Butto...

Страница 3: ...party and the safety of the equipment In order to avoid personal injury and damage to the equipment all safety warnings and cautions such as the following are strictly observed during operation and ma...

Страница 4: ...Do not install the MPPT controller in a location where it may be exposed to lightning strikes Do not install the MPPT controller in a place with a lot of salt spray Good ventilation is required when t...

Страница 5: ...rt WIFI module and GPRS module to expand APP cloud monitoring can be applied to communication base stations households Use systems street lighting systems and field monitoring 2 product features Advan...

Страница 6: ...n It has comprehensive protection functions such as overcharge over discharge over temperature overload reverse connection and so on 3 product appearance 3 1 product appearance pic 2 1 Product appeara...

Страница 7: ...sor External temperature test terminal Measuring battery temperature 8 RS485 Communication port Realize the monitoring of host computer WIFI and GPRS communication III Installation Instruction 1 insta...

Страница 8: ...oller and battery in the same confined space Also do not install in a confined space where battery gas may collect 2 installation instructions Step 1 Choose the installation location Avoid installing...

Страница 9: ...le load temperature sensor monitoring background Connect the battery load PV module temperature sensor monitoring background host computer WIFI module GPRS module in turn disconnect all switches durin...

Страница 10: ...of batteries you need to set the corresponding battery type and series number For details please refer to the relevant settings of the PC host computer or APP manual Caution 1 Danger of electric shoc...

Страница 11: ...shows the diameter of the copper wire according to the current level The actual cable size is greater than or equal to the data in the table Table 3 2 cable size 6 Communication port description Photo...

Страница 12: ...ght status definition Remar ks 1 Fault indicator red Extinguished Working normally no fault 2 Constantly light on error 3 Charging indicator yellow Light off No charging 4 Light on MPPT charging 5 Slo...

Страница 13: ...e key Exit the setup interface button Function 1 display page on page display function 2 parameter setting plus Function 1 Display page under parameter function 2 parameter setting minus UP and DOWN b...

Страница 14: ...Charge The field lights up and displays the current battery charging Icon name definition Function Description day The icon lights up to indicate daylight night The icon lights up to indicate the nigh...

Страница 15: ...d flashes BCV Boost charge The field lights up to set the battery to raise the charging voltage and during the lifting charging phase the field flashes ECV Equalizd charge The field lights up to set t...

Страница 16: ...4 Setup operation 4 4 1 General parameters view Press the Settings set button in standby mode enter the parameter view settings interface and press the SET key to enter the U under R under U over R o...

Страница 17: ...interface to exit the setting interface return to the standby interface other conventional parameter settings are similar to the undervoltage setting Figure 4 4 General Parameter Settings Under voltag...

Страница 18: ...or DOWN button at this time Set the system ID address 4 4 5 For the setting method of connecting the PC to PC or APP WIFI or GPRS mode please refer to the corresponding PC manual and APP manual respec...

Страница 19: ...rotection The controller has its own temperature sensor When the temperature is higher than the set value the charging will stop When the temperature is lowered it will automatically start to work Hig...

Страница 20: ...voltage is lower than device startup voltage Heat sink overheatin g Red light on flashes 1 The ambient temperature is too high the heat dissipation of the equipment is poor and the fan is not well ven...

Страница 21: ...damage to the controller or even other equipment of the user Note Danger of electric shock When doing this you must ensure that all power to the controller has been disconnected before performing the...

Страница 22: ...0 VII Device parameters 1 System parameter table parameter name Parameter value and adjustable range MODEL YN CA YN CB YN CC YN CD Current rating A 10 20 30 40 50 30 40 50 60 70 50 60 80 100 120 Maxim...

Страница 23: ...V 24V battery system 40V 80V 24V battery system 80V 145V 48V battery system 160V 240V 48V battery system 160V 240V 96V battery system System identification voltage range V 12V battery sysem DC9V DC16V...

Страница 24: ...Charge limit voltage v 10 5 15V 21 30V 49 70V 12 6V Boost charge v 10 5 15V 21 30V 49 70V 12 3V Boost charge return v 10 5 15V 21 30V 49 70V 12V Float voltage v 10 5 15V 21 30V 49 70V 12 3V Over disch...

Страница 25: ...YN C Buck series solar charge controller 23 pic 8 1 YN CA Installation diamenion pic 8 2 YN CB Installation dimension...

Страница 26: ...YN C Buck series solar charge controller 24 pic 8 3 YN CC Installation diamenion pic 8 4 YN CD Installation diamension...

Страница 27: ...probe 1 set optional 4 Monitoring cd software 1 piece optional 5 RJ45 to USB module 1 piece optional 6 1 5m Special network cable 1 piece 7 Host computer communication instructions 1 piece 8 RJ45 to W...

Отзывы: