background image

 

p.9

 

Anglerfish Crea�ve Ligh�ng

 | 

Anglerfish Trigger V

2.0 

 

Single core cable

are

 

prone to failure and will not func�on 

properly with the Anglerfish Trigger.

 

In some situa�ons,

 

salt and dart accumulates on the surface 

of 

the remote strobe

’s 

op�cal bulkhead. Inspect the 

bulkhead for debris, salt or fouling. Cleaning the inside of 

both 

the remote strobe and the trigger op�cal bulkhead

with rubbing alcohol and Q

-

T

ips 

will ensure maximum light 

transmission

 

and op�mal 

prepe

rformance. 

 

Some strobes with weak light sensors may not fire while 
using the op�cal cable. In this situa�on please use the 
electrical cable. 

    

Remote Strobe Triggering Randomly: 

It is unlikely that the remote strobe fires randomly. However, 
if this happens it means that the Nikonos bulkhead or the 
sync cable connect

ed 

to the strobe has been flooded. Turn 

off the strobe and assess the cable o

-

rings for damage or 

debris.   

Содержание TRIGGER V3.0

Страница 1: ...USER GUIDE ANGLERFISH TRIGGER V3 0 ...

Страница 2: ......

Страница 3: ... Sheet p ii Anglerfish Crea ve Ligh ng Anglerfish Trigger V2 0 REVISION NUMBER DATE DESCRIPTION REV A DEC 2016 DRAFT REV 0 JAN 2017 ISSUED FOR PRINT REV 1 MAY 2017 UPDATED FOR V2 0 REV2 JAN 2018 UPDATED FOR V3 0 ...

Страница 4: ...2 0 Table of Contents TABLE OF CONTENTS I QUICK START 1 FEATURES 2 OPTICAL SYNC CABLE 2 ELECTRONIC SYNC CABLE 3 TURNING ON 4 TURNING OFF 6 LOW BATTERY INDICATOR 6 CARE MAINTENANCE 6 REPLACING BATTERY 6 TROUBLESHOOTING 7 SPECIFICATION 10 COMPLIANCE 10 ...

Страница 5: ...rigger V3 0 2 Nikonos bulkhead cap 3 Opera on manual user guide 4 Clear acrylic dome cover 5 CR2 Batery included and installed 6 Op cal or electrical sync cable not included You will need an op cal sync cable or an electronic flash sync cable with a Nikonos 5 pin connector to connect the Anglerfish Trigger to the remote strobe ...

Страница 6: ...sensors C Nikonos bulkhead c w cap D Sea Sea type op cal bulkhead E Velcro e groove F Cover Optical Sync Cable The Anglerfish Trigger can trigger a remote strobe via an op cal bulkhead The op cal bulkhead is located on the back of the trigger This feature allows the trigger to connect to A B F D E C ...

Страница 7: ...ity single strand cables will result in high atenua on of light and reduc on in the trigger s performance Avoid bending the fiber op cs cable If possible use the shortest cable available Electronic Sync Cable Anglerfish Trigger is also equipped with a NikonosTM cable bulkhead to trigger the remote strobe electronically Only use genuine Sea Sea brand Nikonos cables or similar cables Nikonos bulkhead ...

Страница 8: ...th the manufacturer s recommended silicon lubricant Turning On The Anglerfish Trigger is equipped with an accelera on switch that is used to turn the unit on or off To wake up the trigger from sleep mode simply hold the trigger in one hand and strike your wrist against your other hand The impact will wake up the trigger The impact must be axial in the direc on as shown in the figure below ...

Страница 9: ...e the trigger turns on For every impact the menu LED will light up purple If the shock due to impact is not strong enough the menu LED will not light up and the trigger will go back to sleep mode in 3 seconds to conserve power This power up sequence prevents the trigger from turning on its own while subject to random shock Once turned on the trigger will automa cally turn off a er 2hrs of opera on ...

Страница 10: ...enu LED will blink red and blue for five cycles and the trigger will enter the sleep mode To operate the trigger the trigger must be charged Care Maintenance A er each salt water dive your trigger should be soaked or rinsed in fresh water The trigger should soak in fresh water for at least 30 minutes Replacing Battery The Anglerfish Trigger come with a CR2 batery preinstalled To replace the batery t...

Страница 11: ...on The batery cradle has a notch in the botom and will only fit in a correct orienta on inside the housing Only use CR2 batery Any other batery may damage the trigger circuit Troubleshooting Not Turning On If upon impact the purple menu LED does not blink it is likely that the unit s batery has been depleted Batery Notch Housing ...

Страница 12: ...ote strobe remove the fiber op c cable from the unit and inspect the small high power LED inside the op cal bulkhead Operate the camera strobe serval mes and see if the LED blinks while the camera strobe fires If the LED does flash bright the fault could be in the op cal cable or the strobe se ngs Make sure you follow the strobe manufacture s se ngs for opera ng the remote strobe via op cal cable Ins...

Страница 13: ... strobe and the trigger op cal bulkheads with rubbing alcohol and Q Tips will ensure maximum light transmission and op mal preperformance Some strobes with weak light sensors may not fire while using the op cal cable In this situa on please use the electrical cable Remote Strobe Triggering Randomly It is unlikely that the remote strobe fires randomly However if this happens it means that the Nikonos...

Страница 14: ...erged 100 grams 30 grams Compliance Anglerfish Trigger Anglerfish Trigger is constructed from electrical components and parts that are RoHS compliant Anglerfish is a lead fee product This electronic product should not be mixed with general household waste The correct disposal of this product will help prevent any poten al nega ve effect to the environment For disposal please take this product to a des...

Страница 15: ... Anglerfish Crea ve Ligh ng Anglerfish Trigger V2 0 QA QC Check List PCB Tes ng Inspec on Menu Func on and Program Test Op cal Trigger Circuit Test Electrical Trigger Circuit Test Hydrotest 980 kPa Serial No ...

Отзывы: