ES
FR
DE
GB
IT
C139
6195
0
ID
M
English
-
31
-
Use and installation manual
Important
Before making any type of adjustment, activate all the safety devices provided
and decide whether staff at work and those in the vicinity should be informed.
In particular, turn off the gas and water supply taps, cut off the electricity supply
using the master switch and prevent access to all devices which might cause
unexpected health and safety hazards if turned on.
Caution - warning
Adjustments must be carried out by authorised, qualified staff, in accordance
with the relevant legal requirements.
To carry out this operation, proceed as follows.
1 –
Turn off the gas supply tap
(A)
.
2 –
Undo the screws to remove the side panel
(B)
.
3 –
Unscrew the screw
(C)
.
4 –
Connect the pressure gauge
(D)
to the pressure
test point
(E)
.
5 –
Turn the gas supply tap
(A)
back on.
6 –
Switch on the appliance (see page 13) and carry
out a cooking cycle without food at the maximum
temperature.
7 –
Check that the pressure gauge reading complies
with the values (see table at back of manual).
8 –
Switch off the appliance, turn off the gas supply
tap
(A)
, and disconnect the pressure gauge
(D)
and
retighten the screw
(C)
.
9 –
Replace the panel
(B)
and retighten the screws
when the operation is complete.
Once the appliance has been connected (see page 26), proceed to analyse the com-
bustion exhaust gases as described:
1 –
Acquire an exhaust gas analyser and calibrate the instrument in accordance with
the instructions in the operator's manual supplied with it.
2 –
Insert the exhaust gas analyser's measuring pipes into the appliance's exhaust gas
discharge lines.
3 –
Switch on the appliance (see page 13).
4 –
Start the " CO/CO2 Measurement" procedure.
5 –
Check the CO and CO2 emission values first at minimum power (cold), then at
maximum power, and then at minimum power (hot) again.
6 –
Check that the readings obtained are as required by the manufacturer.
7 –
Fill in the relative test report (enclosed) and send it to the manufacturer to activate
the Warranty.
ADJUSTMENTS
8
RECOMMENDATIONS FOR ADJUSTMENTS
CHECKING GAS PRESSURE
CHECKING THE COMBUSTION EXHAUST GASES
50
48
46
44
40
38
36
IDM-39619300900.tif
B
A
E
C
D