Turn left completely unscrewing the connector
to disconnect the cable of the core probe.
–
Replace the core probe by screwing the con-
nector fully.
Keep the appliance at peak efficiency by carrying out the scheduled servicing proce-
dures recommended by the constructor. Proper servicing will allow the best perform-
ance, a longer working life and constant maintenance of safety requirements.
Clean inside the cooling cabinet daily.
Both the cabinet and all the internal components have been designed and shaped to
allow washing and cleaning all parts easily.
–
Before cleaning, defrost the appliance and remove the internal drain.
–
Disconnect the master switch.
–
Clean all components (stainless-stell, plastic or painted parts) with lukewarm water
and detergent.
–
Then rinse and dry without using abrasives or chermical solvents.
Caution - warning
Do not wash the appliance by spraying high-pressure water on the ma-
chine.
Do not rinse with sharp or abrasive tools, especially the evaporator
–
You may clean inside the evaporator after loosening the knobs and rotat-
ing the protection component..
–
Wash the door gasket with water. Accurately dry with a dry cloth. We rec-
ommend wearing protecting gloves throughout the operations.
–
Hand-wash the probe using lukewarm water and a mild detergent or prod-
ucts with biodegradability higher than 90%. Rinse with water and sanitary
solution.
Do not use detergents containing solvents (such as trichloroethylene, etc)
or abrasive powders.
Important
Do not use hot water to wash the probe.
REPLACEMENT CORE PROBE
RECOMMENDATIONS FOR SERVICING
CLEANING THE CABINET