- 10 -
3319970_inst_GB_rev.1
ENGLISH
GB
GAS CONNECTION
ELECTRICAL CONNECTION
Important
Those authorised to carry out this operation
must have experience acquired and certifi ed
in the specifi c sector, must make the connec-
tion to the proper standards, and must com-
ply with all the relevant regulations and legi-
slation.
Once the connection has been made, before
the appliance is put into operation a general
check must be made to ensure there are no
gas leaks.
To make the connection, connect the mains
line to the appliance’s connection pipe, fi tting a
shut-off tap
(A)
to allow the gas supply to be cut
off when necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible posi-
tion and its status (on or off ) must be obvious
at a glance.
Important
The gas supply pipe must comply with the
national requirements in force and must be
periodically examined and replaced if neces-
sary.
Important
The equipment comes with a cable to con-
nect it to the outlet of the disconnecting
switch. If it is necessary to change the cable,
proceed as described below.
Important
The connection must be made by authorised,
skilled personnel, in accordance with the rele-
vant legal requirements, using appropriate and
specifi ed materials.
The appliance is supplied with operating volta-
ge 230V1~N 50 Hz.
1)
If not already present, install a circuit-
breaker
(A)
close to the appliance, with the
following characteristics:
– Thermal breaker device (to adjust see table An-
nexes).
– Magnetic circuit breaker curve B (IEC 60898-1).
– Residual current protection set at 30 mA.
2)
Pull off the knob
(B)
.
3)
Take out the screwsi
(C)
and take down the
dashboard
(D)
to access the electric box
(E)
.
A