N

7

PAUSING AND 

RESTARTING THE 

SENSOR PAD

• Allows you to pause the 

Sensor Pad if you remove 

baby from the cot, e.g. 

for feeding or comforting. 

Ensure to un-pause the 

Sensor Pad before putting 

baby in the cot

OK

NURSERY UNIT

PRESS

PRESS &

HOLD

PARENT UNIT

Note:
• Your Nursery Unit and Parent Unit come pre-paired
• Each time you power ON your Nursery Unit, the internal thermometer will need to calibrate to ensure 

accuracy. This automatic process will take approximately 30 minutes

• The screen of the Parent Unit will flash the out-of-range icon until it displays the room temperature 

and function icons. The connection process should be done within 30 seconds. If this sequence is 

not completed within 30 seconds you will need to switch the units off and start again

• If you turn the Nursery Unit OFF the Out-of-Range Alarm will sound. Turn the Nursery Unit ON again to 

re-establish the link

TEST THE SENSOR PAD

1.  Sources of vibration & movement other than your baby’s can be detected by the Sensor Pad 

and interfere with the performance of your Angelcare monitor. The 

alarm will not sound if it detects movement other than your baby’s

2.  There are 3 sensitivity settings – low, medium and high. The unit is set 

at medium (default) and can be adjusted accordingly

3.  The Sensor Pad will detect false movements if you are touching the cot
4.  The monitor will produce a Rouse alarm single beep tone designed to 

stir baby if no movement has been detected for 15 seconds. If no further 

movement is detected, the main alarm will sound at 20 seconds – a series of continuous beeps

SENSOR PAD FOUR CORNER TEST

1.  Place the Sensor Pad at the approximate centre of baby’s sleeping area and put the mattress 

back in place

2.  Switch ON both Nursery & Parent Units – check both units are paired (connected)
3.  Immediately pat your hand lightly and continuously on a corner of the mattress twice for Sensor 

to detect movement. If movement is detected you will hear a TIC sound every 5 seconds

4.  Step away from the cot
5.  The alarm will sound from the Nursery and Parent Unit after 20 seconds. If the 

Alarm does not sound, ensure everything is setup correctly and try again; 

check battery levels on all units, follow the manual for ‘NO ALARMS’ – the sensitivity 

setting may require lowering by a single level due to other vibrations/movements.

6.  If the alarm sounds, pat your hand lightly on a corner of mattress twice 

for Sensor to detect movement. It may take up to 8 seconds to recognise 

movement and for alarm to stop.

7.   If the alarm continues, even after lightly patting the corner of your mattress twice, adjust the 

sensitivity higher and repeat this test

2

CFO3B_ANGE_Manuel_AC127_ROW.indd   7

19-02-05   08:54

Содержание AC127

Страница 1: ...product WARNING Model AC127 Baby Movement Monitor with Sound OWNER S MANUAL IMPORTANT INTENDED USE This product is NOT intended and should NOT be used to prevent Sudden Infant Death Syndrome SIDS This product is NOT intended to diagnose treat mitigate cure or prevent any disease or condition This is a product to monitor the movement of healthy babies and is not a substitute for parental care CFO3B...

Страница 2: ...E Clean wipe with a dry lint free cloth 13 The Sensor Pad is not suitable for use above age 24 months 14 This product cannot replace responsible adult supervision This product is designed to aid in the monitoring of your child When using the monitor you must still 2 This baby monitor is compliant with all relevant standards regarding electromagnetic fields and is when handled as described in the U...

Страница 3: ...on 29 This product contains a Button Cell Battery and if swallowed can cause internal chemical burns in as little as two hours and lead to death Dispose of used batteries immediately Keep new and used batteries away from children If you think batteries might have been swallowed or placed inside any of the body seek medical attention 30 The Button Cell Battery represents a small part and a choking ...

Страница 4: ...electric shock or fire 42 Unplug this appliance during lightning storms or when not used for long periods of time 43 Servicing DO NOT attempt to service this product yourself as opening or removing covers except battery door may expose you to dangerous voltage or other hazards Power Supply see Technical Specification within this guide 44 Overloading DO NOT overload wall outlets extension cords or ...

Страница 5: ... detected for 20 seconds 1 2 1 Remove the battery cover and insert the battery face with face up 2 Replace the battery cover align 2 dots and click to secure Correct positioning for slatted base 3 3 Remove the mattress from the cot place Sensor Pad Angelcare logo side up on base in approximate centre of mattress It should be centred on the hardboard if your cot requires a hardboard support see IMP...

Страница 6: ...es and not memory foam partial or full hollow frame construction mattresses and water beds Please consult Angelcare if unsure of mattress compatibility The hardboard maintains a constant pressure on the Sensor Pad enabling it to detect the baby s movements even when the baby is at the edges of the cot IMPORTANT 3 SETTING UP THE NURSERY UNIT Note The alkaline batteries not included are a back up po...

Страница 7: ...justed accordingly 3 The Sensor Pad will detect false movements if you are touching the cot 4 The monitor will produce a Rouse alarm single beep tone designed to stir baby if no movement has been detected for 15 seconds If no further movement is detected the main alarm will sound at 20 seconds a series of continuous beeps SENSOR PAD FOUR CORNER TEST 1 Place the Sensor Pad at the approximate centre...

Страница 8: ...you to turn OFF LED ring light Pager press hold Allows you to locate the Parent Unit 5 Speaker 6 Power ON OFF 7 Micro USB port 8 Movement Sensor Pad sensitivity switch 9 Pause Movement Sensor Pad 10 Battery compartment 1 2 3 FRONT SIDE 10 4 6 5 7 8 9 REAR SIDE PARENT UNIT 1 Movement detection indicator TIC 2 Power ON OFF 3 Menu press and hold Exit menu 4 Confirm selection or change function Pause ...

Страница 9: ...ction If movement detection is activated allows you to hear a Tic sound every 5 seconds Activate Deactivate sound nursery transmission Allows you to use your monitor for movement detection only Set VOX function Sound Activated VOX ON Means that it will transmit sounds only when it detects them based on the setting of the sensitivity level To save power after 10 seconds the sound transmission will ...

Страница 10: ...vement alarm If NO movement is detected after 15 seconds you will hear a single TIC pre alarm sound from the Nursery Unit this is the Rouse Alarm If after a further 5 seconds there is still NO movement detected both the Parent Unit and Nursery Unit speakers will emit loud consecutive beeps this is the Movement Alarm Sensor Pad Icon and sound level bar on Parent Unit will flash 2 Out of range alarm...

Страница 11: ...n simply press any button of the Parent Unit 7 TROUBLESHOOTING TAKING CARE OF YOUR RECHARGEABLE BATTERY Ensure that you fully charge your batteries for 10 hours before their first use To maintain maximum battery life it is recommended that you fully discharge your batteries periodically Battery performance can be diminished by leaving the batteries constantly charging If your Parent Unit is not in...

Страница 12: ... seconds on the Power ON OFF button Power Indication of the Nursery Unit will turn green 4 Press and hold the Pause button on the Nursery Unit for 3 seconds The Sensor Pad indicator Light of the Nursery Unit will flash blue BLUE 3 4 The reconnection should be completed within 30 seconds The reconnection is successful when Nursery Unit sounds a confirmation tone MOVEMENT SENSOR PAD NO ALARM Sources...

Страница 13: ...ctrical outlets Check the batteries in both units replace or recharge them if necessary Bring the Parent Unit closer to the Nursery Unit STATIC DISTORTION INTERFERENCES FROM OTHER MONITORS WIRELESS PHONES WALKIE TALKIES ETC Rotate the Parent Unit or move it away from source of interference FEEDBACK LOUD NOISES EMITTED FROM THE PARENT UNIT Move units further apart at least 3 metres apart Decrease v...

Страница 14: ...ntal or consequential damages with regard to this product The warranty also excludes any liability other than what is stated above No other warranty is given This warranty does not cover products and accessories which are not Angelcare branded or any problems that result from usage that is not in accordance with product instructions failure to follow the product instructions or problems caused by ...

Страница 15: ...t and the Sensor Pad is made on 2 4 GHz frequency for Europe Asia Africa Australia Maximum RF Power Transmitted 24dBm 250mW between Nursery Unit and Parent Unit 4dBm 2 5mW between Nursery Unit and Sensor Pad RF Channel no between Nursery Unit and Parent Unit 5 RF Channel no between Nursery Unit and Sensor Pad 79 Hereby Angelcare Monitors Inc declares that this Baby Monitor is in compliance with Di...

Страница 16: ...tely satisfied or have any questions please contact your distributor before returning this product United States and Canada Please contact us at info angelcarebaby com Other countries Find your local distributor by visiting our website angelcarebaby com distributors TO LEARN MORE To learn more watch the set up videos and other functionalities on our website https angelcare zendesk com hc Angelcare...