9
No Water or Not Enough Water
Little or no inlet water supply
Be sure inlet water supply is
getting to the system and that the
Inlet Saddle Assembly is clear
Low inlet water supply pressure Feed water must be at least 50psi;
a booster pump may be necessary
Pre-Filter clogged
Replace Pre-Filter
Membrane Element fouled
Replace the Membrane Element
Product Water Check Valve stuck
Replace the Product Water Check
Valve; consult Angel Water for
assistance
Storage Tank over or under
pressurized
Be sure that the Storage Tank is
set between 7-10psi when empty.
Relieve or add air as necessary
via the spigot near the bottom of
the tank (tank must be empty for
accurate psi reading)
Over-use
Allow the System to produce
more water, or replace the system
with a higher gallon per day
membrane
Female Tank Adaptor valve is in
the OFF position
Open the Female Tank Adaptor
valve such that it runs parallel to
the incoming tubing
Low Flow From Long Reach
Faucet or Icemaker
Low water production
See “No Water or Not Enough
Water”
Storage Tank has lost air pre-
charge
Be sure that the Storage Tank is
set between 7-10psi when empty.
Relieve or add air as necessary
via the spigot near the bottom of
the tank (tank must be empty for
accurate psi reading)
Storage Tank diaphragm slippage
Replace Storage Tank and
Post-Filter
Post-Filter and/or Polishing Filter
clogged
Replace Post-Filter and/or
Polishing Filter
Female Tank Adaptor valve is in
the OFF position
Open the Female Tank Adaptor
valve such that it runs parallel to
the incoming tubing