INSTALLATION
This Manual will detail the Installation and Operation of the Filter-Mate
system, with notes where the Filtronic II System differs.
Both the Filter Mate and Filtronic II Systems enable the user to safely and efficiently filter the cooking oil or
shortening from a fryer in a banked row while the other fryers in that row are still being used. Even though
these two Filtration Systems are slightly different in physical dimensions and design, the Installation and
Operation is basically the same.
FILTER ELECTRICAL SPECIFICATIONS
Please make sure that your desired filter location has electrical supply factors that are suitable for this product.
Requirements are
120 Volts, 60 Hz, 8 Amps, 1-phase, three-wire connection, including an electrical
ground.
!
Electrical Grounding Instructions
This appliance is equipped with a three-prong (grounding) plug for
your protection against shock hazard, and should be plugged
directly into a properly grounded, three-prong receptacle. DO NOT
cut or remove the grounding prong from this plug.
FILTER UNIT PREPARATION
(Refer to Photos On Page 4)
1.
Assemble filter envelope to filter screen by sliding the envelope over the filter screen, folding
back the open end over the filter screen. Make sure the hole in the filter envelope fits over the
fitting on the filter screen.
2.
Assemble filter envelope clip over folded back end of envelope and over fitting on filter screen.
3.
Attach knurled retaining nut onto fitting on screen, securing the assembly.
4.
Attach quick-connect coupling on drain tube to knurled retaining nut.
5.
Place filter unit into the filter tank using the lift-out handle.
6.
Connect the filter assembly to the pump using the quick-connect assembly.
7.
Put the filter tank cover on the tank.
8.
Slide the filter tank unit into its location under the fryers or in the filter cabinet.
9.
Make the connection from the fryer return line to the filter pump with the quick-connect fitting.
10.
Plug the cord on the side of the filter unit into the receptacle on the fryer frame. Make sure that
the power switch located on the side or top of filter unit is ON.
WARNING
!