How to operate

 

 

Suggested air pressure is 1.5 to 2.0 bar (21 to 29 PSI). 

 

Recommended paint viscosity differs according to paint property 

and painting conditions. 12 to 18 sec. / Ford cup#4 is recommendable. 

 

Keep fluid output as small as possible to the extent that the job will 

not be hindered. It will lead to better finishing with fine atomization. 

Set the spray distance from the gun to the work piece as near as   

possible within the range of 100

200 mm (7.9

9.8 in). 

 

Maintenance

 

and inspection

 

 

                                                                                                  

 
 
-

First release air and pressure fully according to item No. 3 of “Improper use of equipment” of WARNING on page 2. 

-

Tip of fluid needle set has a sharp point. Do not touch the tip of needle valve at the maintenance for protection of the human body. 

-Be careful not to damage the tip of fluid nozzle or must not put your hand on it. 

-

Only an experienced person who is fully conversant with the equipment can do maintenance and inspection. 

 

 

 

-

Never use commercial or other parts instead of ANEST IWATA original spare parts.

 

-Never immerse the whole gun into liquid such as thinner. 

-Never soak air cap set in solvent for extended period even if cleaning. It may cause defective pattern. 

-Never damage holes of air cap a fluid nozzle and fluid needle. 

 

Step-by-step procedure 

   

1.Pour remaining paint to another container.  Clean fluid passages and air cap set.. 

  Spray a small amount of thinner to clean fluid passages. 

1. Incomplete cleaning can fail pattern shape and uniform particles. 

Especially clean fully and promptly two-component paint after use. 

2.Clean each section with brush soaked with thinner and wipe out with waste   

cloth. 

 

2. Soaking whole automatic spray gun in solvent may cause automatic spray gun malfunction.   

Also soaking air cap set itself for extended period.    

When cleaning, never scratch each hole of air cap set and fluid nozzle, and fluid needle set. 

3. Before disassembly, fully clean fluid passages. 

3. During disassembly, do not scratch seat section. 

(1)Disassemble fluid nozzle.   

Use ring spanner, box wrench or optional exclusive spanner (code 03538600)   

to remove fluid nozzle.   

(1)Remove fluid nozzle after removing fluid needle set or while keeping fluid needle pulled, in 

order to protect seat section. 

(2)Disassemble fluid needle set.    

You do not need to remove fluid adj. guide set from gun body. Remove fluid adj. knob 
and fluid needle spring, and then pull out fluid needle spring, and then pull out fluid 
needle set from back of fluid adj. guide set..

 

(2) Be careful when handing tip of fluid needle set since it is sharp. 

Disassemble fluid adj. guide set as little as possible. 

4. When you want to adjust fluid needle packing set, first tighten it by hand while fluid 

needle set remains inserted. Then tighten it further about 1/6 turn (60-degree) by 
spanner.   

  When you remove needle packing set, do not leave plastic piece of needle packing   

set in the gun body. 

                          
                            

4. If you tighten fluid needle packing set too much, fluid needle set will not move smoothly, 

resulting in paint leakage from tip of fluid nozzle. Try to adjust it carefully while pulling trigger 
and confirming movement of fluid needle set. 
When you tighten it too much, first fully loosen it and then tighten it again carefully. 

5.In order to assemble air valve, first assemble air valve & air valve spring & fluid adj. 

guide set together. Next, insert fluid needle set into fluid adj. guide set , then fit it to 
gun body set and screw fluid adj. guide set. 

5. If you try to fit air valve spring and air valve to gun body set without fluid needle set, air 

valve will not be fitted correctly and lop packing inside fluid adj. guide set will be 
damaged. 

6.Turn pattern adj. knob or air adj. knob counterclockwise to fully open. And then 

tighten pattern adj. set or air adj. set.. 

6. If pattern adj. Knob or air adj. Knob is not fully opened, tip of it can contact and damage 

fluid nozzle and cause seizure of thread. 

 

              

Where to inspect 

Parts replacement standard 

1. Each hole passage of air cap and fluid nozzle 

Replace if it is crushed or deformed. 

2. Packing and O ring 

Replace if it is deformed or worn out. 

3.Leakage from seat section between fluid nozzle and fluid needle set 

Replace them if leakage does not stop after fully cleaning fluid nozzle and fluid needle set.   
If you replace fluid nozzle or fluid needle set only, fully match them and confirm that there is no leakage. 

NOTE:HOW TO ASSEMBLE FLUID ADJ.SET.

   

1.Assemble fluid adj. guide to body set tightly. 
2.Insert scale plate into fluid adj. guide. 
3.Match  3  on the scale 
plate up to the gun top and 
then tighten Hex. Nut.

 

 

 
 
 
 
 
 

 

 

The gun should be held so that it is perpendicular to the surface of 

the work piece at all times. Then, the gun should move in a straight 

and horizontal line. Arcing the gun causes uneven painting. 

 

100

200 mm 

(7.9

9.8 in)

 

×

 

×

 

How to lock fluid adj. knob

 

4.Turn fluid adj. screw clockwise to the end. 
5.Loosen fluid adj. screw 5/8 of a turn (225

) counterclockwise. 

 
6.Insert fluid adj. knob into fluid adj. screw. 
7.Screw fluid adj. lever while matching the lever to   