Problems and remedies
●
If some problem occurs, refer to the chart below.
The asterisk※marked items in the “remedies” column indicate problems which are difficult for the user to handle. In such case, contact
the shop which sold it to you or our local agent.
Problems
Causes
Remedies
Motor does not operate
Electric source is not turned on.
Turn on electric source.
Safeguard activates.
Turn off electric source switch, exhaust compressed air
and turn electric source switch on again in about 15
minutes.
Voltage is low.
※Contact local electric company.
Seizure of compressor
※Repair.
Pressure does not rise or it
takes time for pressure to rise
Air leaks from each connection and piping.
Tighten or replace parts.
Abnormal sound or vibration
Placement failure
Wear inside compressor
Parts are loosened.
Place evenly(Install on 4 legs)
※Repair
Tighten
Please contact your local Anest Iwata agent for inquiries.
3176, Shinyoshida-cho, Kouhoku-ku, Yokohama 223-8501 Japan
No.T222-02
コードNo.08303241
※Main causes for activating motor safeguard.
●When, operating compressor more than 40min (rated-time)
●When, starting or operating compressor with low voltage.
(Including usage of extension cord and/or multiple-tap)
●
When, operating compressor with no cooling effect such as high ambient temperature
and /or being hermetically closed.