PREPARATION 

 

The recommended supply air pressure ranges from 1.7 to 2.0 bar in order to obtain best flow efficiency. 
Keep the distance between the spray gun and painted surface ranging from 100 to 200 mm. 
Maintain liquid outflow at a minimum level within a range that which will allow uninterrupted  work. 
This will guarantee a higher quality of applied coat owing to better material atomisation. The spray gun should always be 
held perpendicular to the painted surface and moved along a horizontal straight line. 
The viscosity of the material being applied should range from 15 to 23 sec., depending on its characteristics and painting 
conditions. (Recommended Ford cup no. 4.) 
 

MAINTENANCE 

 

ATTENTION 
CUT OFF THE COMPRESSED AIR SUPPLY HOSE AND EMPTY THE TANK CONTAININGTHE LACQUERING 
MATERIAL BEFORE COMMENCEMENT OF ANY SERVICING AND MAINTENANCE OPERATIONS. PROCEED WITH 
CARE DURING THE SPRAY GUN DISASSEMBLY SO AS NOT TO GET HURT IN CONTACT WITH SHARP 
ELEMENTS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE ATTEMPTING THE SPRAY GUN 
DISASSEMBLY.  
 
1)  Remove paint residues and wash conduits and the nozzle by spraying a small amount of solvent through the spray 
gun. 
     Careless washing may result in disturbances in the jet shape. 
     In case of binary materials - wash the tool immediately after use. 
2)  Clean other spray gun elements using the brush provided. 
3)  Carefully wash paint flow conduits before the spray gun disassembly. 
4)  Disassemble the nozzle after having removed the needle or with the release trigger pressed - in order to protect the 
nozzle from damage. 
5)  Assemble the needle unit by screwing in the needle seal manually, and then carefully tighten it up with a spanner/key. 
Adjust the seal pressure by releasing the trigger and checking if the needle returns to its “closed” position quick enough 
and all the way. 
6)  Turn the jet adjustment knob anticlockwise, until it reaches its full opening position, and then tighten up the pilot 
sleeve in the spray gun body. 
 
ATTENTION 

 

-

 

Use only original ANEST IWATA spare parts. 

-

 

Never immerse the whole spray gun in a solvent. 

-

 

Protect head holes, nozzle and needle against damage. 

 

SPARE PARTS 

 
DESCRIPTION 

NUMBER   

DESCRIPTION 

NUMBER   

HEAD 
NOZZLE AND NEEDLE 
NOZZLE 
NEEDLE 
NEEDLE SEAL 
NEEDLE SEAL PRESSING CLAMP 
BODY 
AIR INLET TERMINAL 
PAINT TANK TERMINAL 
JET WIDTH REGULATOR 
AIR VALVE SEAT 
SEAT SEAL 
AIR VALVE 
VALVE SPRING 
PILOT AND SEALING SLEEVE 


2     

  

 

2-1   

 

2-2   

 




5-1 
5-2 


7-1    

 

8     

   

 


10 

 

NEEDLE SPRING 
NEEDLE KNOB 
AIR VALVE PUSHER 
AIR FLOW CONTROL KNOB 
RELEASE TRIGGER PIN 
RELEASE TRIGGER 
BLOCKING RING 
FILTER 
BRUSH 
INSTRUCTION MANUAL 

11 
12 
13    

   

 

14 
15 
16 
17 
18 
19 
20 

 
 
 

  Marked parts require 

periodical replacement when 
they wear out 
 
 
 
ATTENTION: 
When ordering spare parts, 
specify the spray gun model, 
name and number of part, head 
number, and numbers of nozzle 
and needle. 

 

 

Отзывы: