AIRSLIM [L]

 

 
 

 

19

 

 

5.8

 

Guy Wires Fixation (Optional) 

When the extensión rod esceeds one meter, it is needed guy wires fixation to secure the fan, in order to avoid 
oscillations.  The  extension  rod  must  be  ordered  specially  prepared  with  four  perforations  to  connect  the  four 
safety cables.

 

These must be introduced into the perforations at a 45º angle, as shown in the following picture: 

 

 

 

 

All  steel  cables  must  be  perfectly 
tensioned  by  the  leveler  to  ensure 
that the extension bar is upright. 

 

CAUTION! 

 

Fasten the guy wires clamps correctly to ensure that they cannot be unscrewed.

 Failure to do so may 

result in equipment damage. 
 

 

45 degrees of 

inclination 

 

To connect with the 

eyebolts 

 

90 Degree 

Содержание AIRSLIM 400L

Страница 1: ...AIRSLIM L Installation Manual Issued June 2020 ANIM14DI Rev D ...

Страница 2: ...ion 11 09 2019 B Fixing and control connections 29 01 2020 C Update Technical Characteristics 03 06 2020 D Update Fixation System Technical documents are regularly updated Anemoi reserves the right to modify the contents of this manual in full or in part without warning ...

Страница 3: ...s 12 5 3 Ceiling Fixation 12 5 4 Extension Rod Assembly 13 5 5 Motor Assemby 16 5 6 Safety Cable Installation 17 5 7 Controller Installation 18 5 8 Guy Wires Fixation Optional 19 5 9 Blades Assembly 20 5 10 Cover Fixation 21 6 ELECTRICAL INSTALLATION 22 6 1 Connectors and Switches Location 23 6 2 Power Connections 24 6 3 Control Connections 25 6 4 Multi Fans Installation 26 6 5 Wiring installation...

Страница 4: ...other accidents Ensure that the wires are held securely and protected from abrasion chaffing overload or other damage Risk of serious or fatal electrical shock fire or other accidents Turn Off power to the fan if you detect any damage Risk of serious or fatal electrical shock fire or other accidents Do NOT connect a damaged fan to the power supply Risk of serious or fatal electrical shock fire or ...

Страница 5: ...nd also in winter using the heat located in the top coats of the building The main characteristics are Aluminium blades with matte black end caps Integrated drive fixed to the down rod extension Modbus RS485 connection for controller Fire alarm stop as a NC relay 24VDC generated by the drive In addition in combination with the traditional air conditioning systems the use of fans allows generating ...

Страница 6: ... 50dBA Total weight 66kg 75kg 93kg Operating temperature 10ºC 60ºC without derating Motor type Permanent magnet motor connected by Modbus RS485 FAN PERFORMANCE Airflow 281 198 m3 h 382 082 m3 h 719 478 m3 h Recommended coverage 937 m 1274 m 2398 m Maximum coverage 1312 m 1783 m 3358 m CONTROL Controllers Magnocontrol OPTIONS Extensions Optional rod extensions of 500 800 1000 1500 2000 mm Colour Op...

Страница 7: ...IM L comes in five different diameters The height of the fan can also be adjusted by modifying the length of the extension bar The following figure shows the dimensions of the fan with a standard extension of 650 mm and total height of 1050 mm ...

Страница 8: ...eight mm Weight kg AIRSLIM L Motor 890 890 300 55 5 Blades 3350 420 250 42 4 2 Packing list The following tables include the different pieces sent inside the boxes Please check the status and quantity of the fan equipment and the supporting parts immediately after you have opened the box to make sure that the goods received are in accordance with your order If parts are missing or damaged please i...

Страница 9: ... Nut 4 Extension rod to mounting system M10 70 bolts 2 M10 Spring washer 4 M10 Nut 2 Extension rod to motor M10 70 bolts 2 M10 Spring washer 4 M10 Nut 2 Safety cable Safety cable 1 Clamp for safety cable 4 Drive U shaped clamp 2 M6 12 full thread bolts 4 Blades M8 45 bolts 10 M8 Spring washer 20 M8 Nut 10 Blades box Nº Component name Qty 1 Fan Blades 5 pcs ...

Страница 10: ...e no obstacles in its operating range Failure to do so may result in equipment damage or accident Ensure sign and protect the working area Failure to do so may result in serious injury or death Ensure following any national or local regulation Failure to do so may result in serious injury or death Do NOT install the fan while it is in operation or connected to the power supply Doing so may result ...

Страница 11: ...y to allow the fan take enough air and provide the maximum performance CAUTION Ensure that the minimum distances are achieved Otherwise the fan could be damaged It is recommended to protect the fan if there is the possibility to receive impacts CAUTION Protect the fan if there is the possibility to receive impacts Otherwise the fan could be damaged ...

Страница 12: ... Wire stripper 1 9 Insulating tape 1 5 3 Ceiling Fixation The Anemoi AIRSLIM L comes with mounting brackets to anchor the fan to the ceiling As standard all tooling is provided so that the fan can be mounted in I beams concrete beams and directly to the ceiling The fan is prepared to be installed in inclined roofs Part list 1 M12 55mm Bolts 4x 2 M12 Spring washer 8x 3 I Beam Clamp 2x 4 I Beam Spac...

Страница 13: ...n will be installed incorrectly The extension rod is assembled to the ceiling fixation by the cardan joint The cardan joint allows also the fan to make free oscillation and to find its own level position specially for inclined roofs The extension rod is assembled to the ceiling fixation by the Screws M10 x70mm provided by applying a tightening torque of 60Nm The extension rod has a rectangular hol...

Страница 14: ... Use the level so that the extension bar is fully vertical 1 Lock bolts nuts 4x Tools 19mm Wrench 19mm Socket Torque Wrench Torque 100 NM CAUTION Ensure that the M10 motor extension bolts are correctly fastened Failure to do so may result in equipment damage Ensure that the extensión rod is completely vertical and fixed Failure to do so may result in equipment damage ...

Страница 15: ...ting the height at which the fan is installed The power cables control cables and safety cable must pass through the ceiling bracket and through the extension bar The power and control cables will exit through the side hole while the safety cable through the bottom The following image shows the position of the cables CAUTION Ensure that the cables pass correctly through the specific holes and that...

Страница 16: ...ent damage The motor is fixed to the extension rod by the Screws M10x70mm provided by applying a tightening torque of 60Nm The cables coming out of the motor must be on the same side as the rectangular window of the extension rod The safety cable must pass through the motor through the center Due to the weight of the motor it is recommended that it be raised by two people to avoid personal injury ...

Страница 17: ...he steel safety cable around the beam forming a closed loop The safety cable must be fixed with the two cable clamps The ring clamps are included in the motor box Part list 1 CAT 6 Shielded Data Cable 2 Power cable 3 Safety cable 4 Clamp for safety cable 4x Cables 1 2 will come out of the square hole on side of the Drop Tube as illustrated Cable 3 is attached to the motor and is feed upward SAFETY...

Страница 18: ...be passed through this hole before proceeding to screw the plate to the extension Use U shaped clamps and four M6 screws provided by applying a tightening torque of 5Nm The following picture shows the installation of the control board Part List 1 Drive unit 2 U shaped clamp 3 M6 12 full thread bolts Tools 10mm Socket Torque Wrench Torque 10 NM Once the drive is fixed it must be screwed and closed ...

Страница 19: ...tions to connect the four safety cables These must be introduced into the perforations at a 45º angle as shown in the following picture All steel cables must be perfectly tensioned by the leveler to ensure that the extension bar is upright CAUTION Fasten the guy wires clamps correctly to ensure that they cannot be unscrewed Failure to do so may result in equipment damage 45 degrees of inclination ...

Страница 20: ...ying a tightening torque of 37Nm as shown in picture Part list 1 Blades 5x 2 M8 Spring washer 20x 3 M8 Locked nut 10x 4 M8 45 Bolts 10x Tools 13mm Wrench 13mm Socket Torque Wrench Torque 30 NM CAUTION Tighten the blade screws correctly Failure to do so may result in incorrect installation Check that there are no objects that can avoid the blades rotation Failure to do so may result in equipment da...

Страница 21: ...IRSLIM L 21 5 10 Cover Fixation The fan includes a special cover to hide the screws Use the screws provided to cover the bottom of the motor as shown in picture Part List 1 Bottom Cover 1x 2 M6x12 Screw ...

Страница 22: ...Check that power supply is disconnected before starting the installation All cabling must comply with national and local regulations on cable cross sections and ambient temperature Copper 60 C 75 C conductors are recommended Follow any national or local regulation regarding electrical installations CAUTION Follow national and local electrical regulations Failure to do so may result in serious inju...

Страница 23: ...the motor This board also has several switches that allow you to configure communications The following image shows the location of the connectors and switches Nº Description 1 Power connector GND L1 L2 L3 2 Control cables connector 3 Switch 2 4 Engine sensors connector 5 Switch 1 6 Motor power connector 7 Motor ground connection 8 Switch 3 ...

Страница 24: ...cal voltage GND L1 L2 L3 It is possible to use both shielded and unshielded cables with a maximum section of 4mm The electrical cables must be arranged in a separate circuit from the control cables to avoid interference WARNING Do NOT use wires with worn or damaged insulation Doing so may result in serious or fatal electrical shock fire or other accidents Ensure that the wires are held securely an...

Страница 25: ...connected directly to the fan control board using shielded cable type modbus cable RS485 2x2x0 50 mm POSCY The control connections of the fan are located in connector 2 of the figure in section 6 1 The following figure shows the detail of the control connectors Optional use for control command power Communications wiring ...

Страница 26: ...must be made in series The last fan of the series the switch must be configured as ON OFF OFF and in the rest of the fans as OFF OFF OFF The location of switch 1 can be seen in the figure of section 6 1 The next figure shows the correct connections WARNING The earth meshes of each cable section must remain together Failure to do so may lead to communication errors Connect only one end of the earth...

Страница 27: ...rity Without parity The location of switch 2 can be seen in the figure of section 6 1 Setting pins 1 to 5 of switch 2 as follows as long as Pin8 is in OFF position Adress Pin1 Pin2 Pin3 Pin4 Pin5 1 2 ON 3 ON 4 ON ON 5 ON 6 ON ON 7 ON ON 8 ON ON ON 9 ON 10 ON ON 11 ON ON 12 ON ON ON 13 ON ON 14 ON ON ON 15 ON ON ON 16 ON ON ON ON 17 ON 18 ON ON 19 ON ON 20 ON ON ON 21 ON ON 22 ON ON ON 23 ON ON ON ...

Страница 28: ...as an antenna Communication cables that are not used have to be cut and left inside the shielded tube as shown below 3 Please keep always a distance of at least 20cm between the power and the data cable If both cables must cross at some point please ensure that they do so at a 90º angle to prevent interference WARNING Do not strip the communication cable more than 5cm Failure to do so may lead int...

Страница 29: ...wer drive as shown below WARNING Maintain a minimum distance between electrical and communications wiring Failure to do so may lead interferences Avoid power zones Failure to do so may lead interferences Communications cable must be performed shortly and directly Avoid power zones marked in red ...

Страница 30: ... make any noises or vibrations Check that the blades have not received any impact Yearly Check that there no alarms or faults in in the control screen Ensure that the extension rod screws are properly tightened Ensure that the anchoring screws are properly tightened Ensure that the blade screws are properly tightened Clean the blades using a wet cloth Check that the safety cable is properly fasten...

Страница 31: ...www anemoifans com ...

Отзывы: