AIRPOLE
Installation Manual
Issued January 2020
ANIM17AI Rev. A
Страница 1: ...AIRPOLE Installation Manual Issued January 2020 ANIM17AI Rev A...
Страница 2: ...LE 2 UPDATES DATE UPDATE DESCRIPTION 16 01 2020 A First Edition Technical documents are regularly updated Anemoi reserves the right to modify the contents of this manual in full or in part without war...
Страница 3: ...L INSTALLATION 9 4 1 Clearances 10 4 2 Pole Requirements 11 4 3 Floor Fixation 13 4 4 Motor Assembly 13 4 5 Blades Assembly 14 4 6 Motor ventilation Grid Fixation 15 4 7 Cover Fixation 15 4 8 Control...
Страница 4: ...her accidents Ensure that the wires are held securely and protected from abrasion chaffing overload or other damage Risk of serious or fatal electrical shock fire or other accidents Turn OFF power to...
Страница 5: ...air from the ceiling thanks to the motor power This fan is mainly used to increase comfort in summer by generating a smooth breeze even outdoors and can also be used in winter using the heat located i...
Страница 6: ...pm 100rpm 100rpm 80rpm 70rpm Protection degree IP54 IP54 IP54 IP54 IP54 Sound level 50dBA 50dBA 50dBA 50dBA 50dBA Total weight 178kg 206kg 210kg 251kg 255kg Motor type Magnet motor FAN PERFORMANCE Air...
Страница 7: ...60rpm 60rpm Protection degree IP54 IP54 IP54 IP54 Sound level 50dBA 50dBA 50dBA 50dBA Total weight 291kg 293kg 306kg 320kg Motor type Magnet motor FAN PERFORMANCE Airflow 309 600m3 h 385 200m3 h 475 2...
Страница 8: ...ntity of the fan equipment and the supporting parts immediately after you have opened the box to make sure that the goods received are in accordance with your order If parts are missing or damaged ple...
Страница 9: ...prevent anyone from going under the fan It is recommended to fence at least four meters around the lifting equipment Follow any national or local regulation regarding installations in height SAFETY E...
Страница 10: ...hen running If there are lamps above the fan blades change their position if necessary to avoid the strobe effect Ensure that the fan is installed at a height greater than four meters The next figure...
Страница 11: ...11 4 2 Pole Requirements The Anemoi AIRPOLE requires a pole that can be ordered to Anemoi or can be manufactured in the installation country to avoid high transport costs Dimensions of the tube are as...
Страница 12: ...AIRPOLE 12 Recommended dimensions for the floor fixation part are...
Страница 13: ...so may result in equipment damage 4 4 Motor Assembly The AIRPOLE fan is delivered with a bolted flange so that the motor conical cover is correctly fixed to the pole The motor s weight is very heavy...
Страница 14: ...nd fix it using the M6 bolts and the blades retainer It is necessary to tighten the outside bolts first and then the inside bolts using the retainers The next figure shows the blades assembly The next...
Страница 15: ...onical protection includes a special grid for ventilation that ventilates it Use the screws provided to fix it as follows 4 7 Cover Fixation The motor includes a special cover to protect the fan hub b...
Страница 16: ...gned to be screwed directly onto a wall To that end it includes a hole on each corner Before drilling the wall hold the control box in the desired position and mark the screw location Please install t...
Страница 17: ...ting the installation Failure to do so may result in serious injury or death Do NOT install the fan with wet hands Failure to do so may result in serious injury or death Do not change the VFD configur...
Страница 18: ...ed to recheck that all bolts and nuts are correctly fastened After performing all mechanical and electrical connection steps included in this manual run the fan as follows 1 Change the main switch to...
Страница 19: ...next steps to start the fan 1 Change the main switch to the start position 2 Adjust the potentiometer to the required speed 3 Check the speed in the VFD screen To stop the fan perform the procedure i...
Страница 20: ...or vibrations Check that the blades have not received any impact Yearly Check that there no alarms or faults in the variable speed drive located in the control box Ensure that the extension rod screws...
Страница 21: ...uency drive Check control wires connections Replace the main switch The fan can t start normally The potentiometer is not working correctly Reset the variable frequency drive Check control wires conne...
Страница 22: ...www anemoifans com...