39
Ex.WHiC56,LWHiC56
If the water drain valve (with water fi lter) is covered with debris, the hot water may not run
smoothly, or the unit may produce cold water. Check and clean the fi lter as explained below.
* To avoid burns, wait until the equipment cools down before draining the water.
The appliance will remain hot after it is turned off.
Water Drain Valve (with Water Filter)
* Water will be discharged from the trap plug. Place
a container, etc. to receive the discharged water.
1. Close the water supply valve.
2. Open all hot water fi xtures.
3. Remove the inlet and outlet drain plugs (about 1.7 L:
(L)WHiXC56 and (L)WHiC56, 0.8L: (L)WHiX49
and (L)WHi49, will drain out)
4. Take the water drain valve (with water fi lter) out of
the inlet. (See illustration to right).
5. Clean the water drain valve (with water fi lter) with
a brush under running water.
6. Replace the water drain valve (with water fi lter).
(Take care not to lose the packing.)
7. Close all hot water fi xtures.
8. Open the water supply valve and check that water
does not leak from the drain plugs or water drain
valve (with water fi lter).
Water Supply
Valve
Inlet
Packing
Drain Valve
(with fi lter)
Maintenance (Once a month)