Table 6: Standing heat-loss
Table 7: Maximum kW ratings for auxiliary heating supply
Table 8: Auxiliary heat up times based on maximum immersion input per cylinder
Testing is carried out to BS EN12897:2006
N o m i n a l
Capacity
(Litres)
Per Day
(kWh/24h)
Per Year
kWh/24h)
400
1.72
627
500
2.14
781
800
2.74
1000
1000
3.33
1215
1250
3.60
1314
1450
3.90
1423
2000
4.30
1569
2500
4.50
1642
N o m i n a l
Capacity
(Litres)
Maximum kW ratings
Lower boss
Upper boss
Total kW
400
30
9
39
500
45
12
57
800
45
18
63
1000
45
36
81
1250
54
30
84
1450
54
36
90
2000
54
36
90
2500
54
36
90
N o m i n a l
Capacity
(Litres)
Heat-Up Times
N o m i n a l
Capacity
(Litres)
Heat-Up Times
Maximum kW
Heat-up
Time (mins)
Maximum kW
Heat-up
Time (mins)
400
39
32
1250
84
47
500
57
28
1450
90
51
800
63
40
2000
90
70
1000
81
39
2500
90
87
Notes:
Times based on nominal volume
Times base on 45°C temperature rise