                                                  Andrew Corporation – Base Station Systems Group                                                Page 2 

Proprietary – Use pursuant to Company Instruction 

Functional Blocks: 

 
The OneBase™ Cell Extender subrack is comprised of the following functional blocks: 
 

 

RFIM (Radio Frequency Interface Module):  

 

MCPAs (Multi-carrier Power Amplifiers—850 MHz or 1900 MHz) 

 

SCM (Switch Combiner Module) 

 

Filter Module (850 MHz or 1900 MHz) 

 

PDP (Power Distribution Panel) 

 

Inputs and Outputs 

 

Inputs and Outputs: 

 
The amplifier is powered from a DC supply voltage which can range from 20VDC-to-
30VDC (with a nominal voltage of 27 VDC).  The DC power is brought into the subrack 
at a terminal that is in the back of the subrack.  
  
The RF signal is brought into the RFIM, passes into the amplifers, then through the SCM 
which is blind-mate connected to the amplifiers, and finally into the Filter Modules and 
subsequent antenna ports.  
 
 
 

 

 

 

 

 

 

 

Содержание OneBase Cell Extender

Страница 1: ...Base Station Systems Group Proprietary Use pursuant to Company Instruction OneBase Cell Extender Model OBE DB X Operation Instruction December 20 2006 Version 1 0 Reference Numbers FCC ID S8L OBEMCPA...

Страница 2: ...nalog air interfaces System Specifications System specifications for the OneBase Cell Extender Subrack are Parameter Specification Frequency Bands 850 MHz Band Tx 869 894 MHz 1900 MHz Band Tx 1930 199...

Страница 3: ...Module Filter Module 850 MHz or 1900 MHz PDP Power Distribution Panel Inputs and Outputs Inputs and Outputs The amplifier is powered from a DC supply voltage which can range from 20VDC to 30VDC with a...

Страница 4: ...Andrew Corporation Base Station Systems Group Page 3 Proprietary Use pursuant to Company Instruction System Pictures Front View Rear View...

Страница 5: ...continue operating Critical Conditions which result in sector shutdown preventing any further cellular call traffic MCPA LEDs MCPA LED Status Alarm Severity Possible Failure Modes Green ON Yellow ON...

Страница 6: ...nal temperature above approximately 80 C Green ON Red FLASHING Major 1 Major failure or one or more MCPAs as follows a RF disabled via MCPA panel switch or RFIM command b RF Overdrive gain reduced c D...

Страница 7: ...Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause unde...

Страница 8: ...he time of licensing 5 Multi carrier operation Rated output power of the equipment is for multi carrier operation which is 426 Watts maximum total composite For multiple carriers the total output powe...

Отзывы: